Compact Switching Power Supply

MS2 series

Catalogs View Catalog

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Output Current 1.5 A, 5-V Type MS-E07

MS-E07 - Output Current 1.5 A, 5-V Type

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • UL Recognition(c/us)

Specifications

Model

MS-E07

Input conditions

Input voltage

85 to 264 VAC (50/60 Hz), 120 to 340 VDC*1

Frequency

47 to 63Hz*2

Inputconditions

Input current (100/200 VAC)

0.28/0.16A or less

Efficiency (100/200 VAC)

Leakage current (100/200 VAC)

0.5/1mA or less

Rush current (100/200 VAC)

18, 36 A or less (with a +25°C 77°F cold start)

Output characteristics

Rated voltage

5V

Variable voltage range

±5% (with V.ADJ)

Rated current

1.5A

Ripple/noise voltage

2% (p-p) or less

Input fluctuation

0.5% or less

Load fluctuation

1.0% or less

Temperature fluctuation

Startup time

400ms or less

Output holding time

20 ms or more (100 to 240 VAC)

Protection

Overcurrent protection

Constant current drop method, automatic recovery, 1.9 A or more

Overvoltage protection

Present*3

Display

Display power

Power off memory time

Display resolution

Applicable standards

Safety standards

UL60950, CSA C22.2 number 60950, EN60950

EMC standard

FCC Part 15 B Class A, EN55011 Class A

Limits for harmonic current emissions

EN61000-3-2*4

Other

Parallel operation

Not possible

Series operation

Possible (requires external diode)*5

Cooling method

Natural air cooling

Environmental resistance

Insulation resistance

100 MΩ or more at 500 VDC
(between input and output, between input and FG, and between output and FG)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing) (see the derating characteristics)

Relative humidity

25 to 85 % RH (No condensation)

Withstand voltage

3.0 kVAC 50/60 Hz 1 min (across input and output terminals), 2.0 kVAC 50/60 Hz 1min (across input terminals and PE terminal), 500 VDC 1min (across output terminals and PE terminal)

Vibration resistance

10 to 57 Hz, Double amplitude 0.3 mm 0.01", 57 to 500 Hz, 19.6 m/s2 (2 G), cycle: 5.5 minutes, 2 hours in each of the X, Y, and Z directions

Shock resistance

Peak acceleration: 300 m/s2, 2 times in each of the X, Y, and Z directions

Weight

Approx. 140 g

*1 When applying for safety standards are 100 to 240 VAC, 50/60 Hz.
*2 The rated input voltage and rated frequency when applying for safety standards are 100 to 240 VAC, 50/60 Hz.
*3 To return, turn OFF the input power supply and after leaving it off for 1 minute or more, plug in the input power supply again. The E/F Series is a Zener diode clamp type. It will not restart after the protection circuit operation.
*4 For the MS2-H100, this is applicable only when the load ratio is 70% or less.
*5 The applicable standards do not apply for parallel and serial operations.

Data Sheet (PDF) Other Models