General Purpose Digital Contact SensorGT series

DL-DN1

DeviceNet™ Compatible Communication Unit

SPECIFICATIONS

Select Language

Model

DL-DN1*1

DeviceNetTM specifi cations

Network power supply

11 to 25 VDC (supplied from DeviceNetTM communication power supply)

Indicator

Network status indicator: 2-color (green/red) LED, Module status indicator: 2-color (green/red) LED,
Sensor communication indicator: 2-color (green/red) LED

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*2

Number of
connectable
sensor units

Up to 8 units

DeviceNetTM specifi cations

Compliant functions

Remote I/O communication (polling) Explicit messaging

Address setting

0 to 63 (PGM compatible)

Baud rate (automatically switched)

500 kbps/250 kbps/125 kbps

Maximum cable length

500 kbps

thick cable

100m 328.09' (thick cable)

thin cable

100m 328.09' (thin cable)

250 kbps

thick cable

250m 820.21' (thick cable)

thin cable

100m 328.09' (thin cable)

125 kbps

thick cable

500m 1640.42' (thick cable)

thin cable

100m 328.09' (thin cable)

Power voltage

20 to 30 VDC, including ripple, Ripple (P-P): 10% max. Class 2 (Supplied via connected sensor amplifier)

Power consumption

660 mW or less (at 30 V, 22 mA max.)

Environmental
resistance

Operating surrounding
air temperature

-20 to +55°C -4 to 131°F (no freezing)

Operating surrounding
air humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm 0.06", 2 hours each in X, Y, Z directions

Pollution degree

2

Materials

Main unit case and dust cover: Polycarbonate, DeviceNetTM connector: Polyamide (plug), PUT (socket)

Weight

Approx 80g

*1 For connecting with sensor, please refer to the user's Manual
*2 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.

Measurement Library