Model

GT-H10

GT-H10L

GT-H22

GT-H22L

Measuring range

10 mm 0.39"

22 mm 0.87"

Mechanical response
frequency

10 Hz*1

7 Hz*1

8 Hz*1

5 Hz*1

Repeatability

3 µm 0.12 Mil*2

8 µm 0.31 Mil*2

Measurement force

Downward mounting

1.0 N*3

0.3 N*3

1.5 N*3

0.35N*3

Side mounting

0.9 N*3

0.25N*3

1.4 N*3

0.3 N*3

Upward mounting

0.8 N*3

0.2 N*3

1.3 N*3

0.25N*3

Environmental resistance

Enclosure rating

IP67

IP67

Operating temperature range

-10 to +55°C 14 to 131°F

Operating ambient humidity

35 to 85%RH

Material

Main body case: TYPE430 Stainless steel, Indicator: Polyarylate,
Contact: TYPE304 Stainless steel, TYPE440C Stainless steel, Cable: PVC

Main body case: TYPE430 Stainless steel, Indicator: Polyarylate,
Dust boot: NBR , Contact: TYPE304 Stainless steel, TYPE440C Stainless steel, Cable: PVC

Main body case: TYPE430 Stainless steel, Indicator: Polyarylate,
Contact: TYPE304 Stainless steel, TYPE440C Stainless steel, Cable: PVC

Main body case: TYPE430 Stainless steel, Indicator: Polyarylate,
Dust boot: NBR , Contact: TYPE304 Stainless steel, TYPE440C Stainless steel, Cable: PVC

Weight

Approx115 g (With 2-m 6.6'
connector cable)

Approx135 g (With 2-m 6.6'
connector cable)

*1 At ambient temperature of 23°C 73.4°F
*2 At ambient temperature of 23°C 73.4°F. Read value in the central measuring position when 100 ms is set as the
response time.
*3 The value near the center.

Model

GT-A10

GT-A22

Measuring range

10 mm 0.39"

22 mm 0.87"

Repeatability

3 µm 0.12 Mil*1

8 µm 0.31 Mil*1

Measurement force

Downward mounting

1.0 N*2

1.5 N*2

Side mounting

0.9 N*2

1.4 N*2

Upward mounting

0.8 N*2

1.3 N*2

Number of sliding cycles

3000000 cycles

Environmental resistance

Enclosure rating

IP67 *3

Operating temperature range

0 to +55°C 32 to 131°F

Operating ambient humidity

35 to 85%RH

Applied pressure range

0.35 to 0.5 MPa

Pressure resistance

1.0 MPa

Material

Main body case: TYPE430 Stainless steel,Cylinder: Aluminum alloy,Air joint resin part: Polyacetal,Air joint metallic part: Brass nickel plating,Indicator: Polyarylate, Dust boot: NBR,Contact: TYPE304 Stainless steel, Cable: PVC

Weight

Approx150 g (With 2-m 6.6' connector
cable)

Approx180 g (With 2-m 6.6' connector
cable)

*1 At ambient temperature of 23°C 73.4°F. Read value in the central measuring position when 100 ms is set as the
response time.
*2 The value near the center.
*3 To prevent entry of foreign objects from the exhaust joint, connect the air tube to the exhaust joint.

Model

GT-71A*1

GT-72A*1

GT-75A*1

GT-76A*1

Output

NPN output

Mounting method

DIN rail mount*2

Panel mount

Main unit/Expansion unit

Main unit*3

Expansion unit*3

Main unit*3

Expansion unit*3

Current consumption.

At 12 V

Normal

1140 mW (95 mA) or less

Power saving (Eco)

600 mW (50 mA) or less

At 24 V

Normal

1200 mW (50 mA) or less

Power saving (Eco)

840 mW (35 mA) or less

Display power

Measured value display

6-digit 7-segment LED (red)

Display method

Other displays

2-color, 13-level bar LED display (red, green), indicators (red, green)

Display range

-99.999 to 999.999

Display resolution

1 μm 0.039 Mil

Sampling rate

2000 times/second

Major functions

Preset, Hold, Variable hysteresis, Variable response time, Multiplier setting, Bank function (4 banks),
Self-timing, Power save (eco) mode, Application mode, Calibration function, Core alarm

Control input

Timing input

Input time: 2 ms or more

Preset input

Input time: 20 ms or more

Bank input

HIGH, GO, LOW output

NPN open collector, 50 mA max. 40 V or less
residual voltage: 1 V or less, N.O./N.C. switchable

Response time

hsp (1.5 ms) , 5 ms, 10 ms, 100 ms, 500 ms, 1 s, 5 s

Rating

Power source
voltage

12 to 24 VDC, ripple (P-P) 10% or less*4

Environmental resistance

Operating temperature range

-10 to 55°C 14 to 131°F, No freezing

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z directions

Material

Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: Polycarbonate, Cable: PVC

Accessories

Instruction manual

None

Panel mounting bracket, Protective front cover, Power cable, Instruction manual

Panel mounting bracket, Protective front cover, Power cable, Flat cable for expansion

Weight

Approx 110 g (including Power cable)

Approx 110 g (including Panel mounting bracket, Protective front cover, Power cable)

*1 The amplifier models indicated with “A” at the end of the model code are the upgraded version that provides compatibility with the DL series communication unit. Other models (without “A” at the end of
the model code) are not compatible with the DL series, but compatible with GT-H10/H10L/H22/H22L.
*2 Be sure to mount the DIN rail mounting amplifier on a DIN rail (i.e. the unit should be mounted on the metal DIN plate itself). For additional amplifier unit installation, be sure to use the end unit
(OP-26751).
*3 One main unit and nine expansion units (ten in total) can be additionally installed. For additional amplifier unit installation, each output current must be 20 mA or less.
*4 If additional amplifier units are installed, the power supply voltage is 24 VDC.

Model

GT-71AP*1

GT-72AP*1

GT-75AP*1

GT-76AP*1

Output

PNP output

Mounting method

DIN rail mount*2

Panel mount

Main unit/Expansion unit

Main unit*3

Expansion unit*3

Main unit*3

Expansion unit*3

Current consumption.

At 12 V

Normal

1140 mW (95 mA) or less

Power saving (Eco)

600 mW (50 mA) or less

At 24 V

Normal

1200 mW (50 mA) or less

Power saving (Eco)

840 mW (35 mA) or less

Display power

Measured value display

6-digit 7-segment LED (red)

Display method

Other displays

2-color, 13-level bar LED display (red, green), indicators (red, green)

Display range

-99.999 to 999.999

Display resolution

1 μm 0.039 Mil

Sampling rate

2000 times/second

Major functions

Preset, Hold, Variable hysteresis, Variable response time, Multiplier setting, Bank function (4 banks),
Self-timing, Power save (eco) mode, Application mode, Calibration function, Core alarm

Control input

Timing input

Input time: 2 ms or more

Preset input

Input time: 20 ms or more

Bank input

HIGH, GO, LOW output

PNP open collector, 50 mA max. 30 V or less
residual voltage: 1 V or less, N.O./N.C. switchable

Response time

hsp (1.5 ms) , 5 ms, 10 ms, 100 ms, 500 ms, 1 s, 5 s

Rating

Power source
voltage

12 to 24 VDC, ripple (P-P) 10% or less*4

Environmental resistance

Operating temperature range

-10 to 55°C 14 to 131°F, No freezing

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z directions

Material

Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: Polycarbonate, Cable: PVC

Accessories

Instruction manual

None

Panel mounting bracket, Protective front cover, Power cable, Instruction manual

Panel mounting bracket, Protective front cover, Power cable, Flat cable for expansion

Weight

Approx 110 g (including Power cable)

Approx 110 g (including Panel mounting bracket, Protective front cover, Power cable)

*1 The amplifier models indicated with “A” at the end of the model code are the upgraded version that provides compatibility with the DL series communication unit. Other models (without “A” at the end of
the model code) are not compatible with the DL series, but compatible with GT-H10/H10L/H22/H22L.
*2 Be sure to mount the DIN rail mounting amplifier on a DIN rail (i.e. the unit should be mounted on the metal DIN plate itself). For additional amplifier unit installation, be sure to use the end unit