High-Accuracy Digital Contact SensorGT2 series

GT2-71D

Amplifier Unit, Pulse Output Type

SPECIFICATIONS

Select Language

Model

GT2-71D

Mounting method

DIN rail mount

Power supply voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2

Rating

Power consumption

1,600 mW or less (at 30 V: 53.3 mA or less)

Number of expandable units

Cannot be extended

Indicator lamp

Power (green), alarm (red), pulse output (green), input (green)

Pulse resolution

0.1 μm 0.004 Mil, 0.5 μm 0.02 Mil, 1 μm 0.04 Mil, 10 μm 0.039 Mil (selectable)

Minimum phase difference

0.5 μs, 2.5 μs, 5 μs, 25 μs (selectable)

Control input (origin return)

No-voltage input (with contacts, without contacts), input time: 20 ms or more

Output signal

90° phase difference from the A, B, and Z phases; differential square wave (conforms to EIA-422)

Output signal level

+5 V

Environmental
resistance

Ambient temperature

-10 to +50°C 14 to 122°F (No freezing)

Relative humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, 1.5 mm 0.06", double amplitude, 2 hours in each of X, Y, and Z directions

Materials

Polycarbonate (PC)

Weight

Approx 110 g (including the power supply cable)