High-Accuracy Digital Contact Sensor
|
Model | GT2-H12K |
GT2-H12KL | GT2-H12 |
GT2-H12L | GT2-H32 |
GT2-H32L | GT2-H50 |
|||
|
Detection system |
Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error) | |||||||||
| Measuring range | 12 mm 0.47" |
32 mm 1.26" | 50 mm 1.97" | |||||||
| Resolution | 0.1 μm 0.004 Mil | 0.5 μm 0.02 Mil | ||||||||
| Accuracy (20°C (68°F)) | 1 μm 0.04 Mil (p-p) |
2 μm 0.08 Mil (p-p) | 3 μm 0.12 Mil (p-p) | 3.5 μm 0.14 Mil (p-p) | ||||||
|
Measuring force*1 |
Downward mounting | 1.0 N | 0.4 N | 1.0 N | 0.4 N | 2.1 N | 1.2 N | 3.2 N | ||
|
Side mounting | 0.9 N | 0.3 N | 0.9 N | 0.3 N | 1.8 N | 0.9 N | 2.8 N | |||
|
Upward mounting | 0.8 N | 0.2 N | 0.8 N | 0.2 N | 1.5 N | 0.6 N | 2.4 N | |||
|
Mechanical response | 10 Hz | 4 Hz | 10 Hz | 4 Hz | 6 Hz | 5 Hz | 7 Hz | |||
|
Probe | Carbide ball ø3 | Steel ball ø3 | ||||||||
| Operation indicator |
2-color LED (red, green) | |||||||||
|
Environmental |
Enclosure rating |
IP67 | – |
IP67 | – |
IP67 | – |
IP67 | ||
| Ambient temperature | -10 to +55°C (14 to 131°F) (No freezing) | |||||||||
| Relative humidity | 35 to 85% RH (No condensation) | |||||||||
| Vibration | 10 to 55 Hz, 1.5 mm 0.06", double amplitude, 2 hours in each of X, Y, and Z directions | |||||||||
| Sensor head cable | Optional (M8 connector) | |||||||||
| Materials | Main body | Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR | Main body cast: Zinc die-casting, Indicator: Polyarylate | Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR | Main body cast: Zinc die-casting, Indicator: Polyarylate | Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR | Main body cast: Zinc die-casting, Indicator: Polyarylate | Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR | ||
| Contact |
TYPE304 Stainless steel, super-tough tungsten alloy | TYPE304, 440C Stainless steel | ||||||||
|
Weight (excluding cable) |
Approx. 95 g | Approx. 270 g | Approx. 320 g |
|||||||
|
Accessories | Refer to the instruction manual. | |||||||||
| Type | Standard/Low stress (L) type (Sensor head for 12 mm 0.47") |
Standard/Low stress (L) type |
||||||||
|
*1 Value at center of measuring range. | ||||||||||
|
Model | GT2-A12K |
GT2-A12KL | GT2-A12 |
GT2-A12L | GT2-A32 |
GT2-A50 | |||
| Detection system | Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error) | ||||||||
| Measuring range | 12 mm 0.47" | 32 mm 1.26" | 50 mm 1.97" |
||||||
|
Resolution | 0.1 μm 0.004 Mil |
0.5 μm 0.02 Mil | |||||||
| Accuracy (20°C (68°F)) *1 |
1 μm 0.04 Mil (p-p) | 2 μm 0.08 Mil (p-p) | 3 μm 0.12 Mil (p-p) | 3.5 μm 0.14 Mil (p-p) |
|||||
|
Measuring force *2 |
Downward mounting | 1.2 N | 0.4 N | 1.2 N | 0.4 N | 2.1 N | 3.2 N |
||
|
Side mounting | 1.1 N | 0.3 N | 1.1 N | 0.3 N | 1.8 N | 2.8 N |
|||
|
Upward mounting | 1.0 N | 0.2 N | 1.0 N | 0.2 N | 1.5 N | 2.4 N |
|||
|
Operation indicator |
2-color LED (red, green) | ||||||||
| Applied pressure range | 0.25 to 0.5 MPa | ||||||||
| Pressure resistance |
1.0 MPa | ||||||||
|
Environmental resistance |
Enclosure rating | IP67 *4 |
– | IP67 *4 |
– |
IP67 *4 | |||
| Ambient temperature | 0 to 55°C (32 to 131°F) (No freezing) | ||||||||
| Relative humidity | 35 to 85% RH (No condensation) | ||||||||
| Vibration | 10 to 55 Hz, 1.5 mm 0.06", double amplitude, 2 hours in each of X, Y, and Z directions |
10 to 55 Hz, 1.5 mm 0.06", double amplitude, 2 hours in each of X, Y, and Z directions*5 | |||||||
|
Materials | Main body | Main body case: Zinc die-casting; Cylinder
part: Aluminium alloy; | |||||||
| Dust boot | NBR |
– |
NBR | – | NBR | ||||
| Contact *3 |
TYPE304 Stainless steel, super-tough tungsten alloy | TYPE304, 440C Stainless steel | |||||||
|
Sensor head cable |
Optional (M8 connector) | ||||||||
| Weight (excluding cable) | Approx. 145 g | Approx. 340 g |
Approx. 405 g | ||||||
| Accessories | Refer to the instruction manual. | ||||||||
|
Type | Standard / Low stress (L) type (Sensor head for 12 mm 0.47") |
Standard type (Sensor head for 32 mm 1.26"/50 mm 1.97" range) |
|||||||
| *1 Value when
ambient temperature is 20°C
(68°F) | |||||||||
|
Model |
NPN | GT2-71N | GT2-72N | GT2-71CN | GT2-72CN | GT2-71MCN | ||
| PNP |
GT2-71P | GT2-72P | GT2-71CP | GT2-72CP | GT2-71MCP | |||
|
Mounting method |
DIN-rail mount | |||||||
| Type | Standard loose wire type |
Standard connector type |
Analog output, connector type | |||||
| Main unit/Expansion unit *1 | Main unit | Expansion unit | Main unit |
Expansion unit | Main unit | |||
| Power supply voltage *1 |
10 to 30 VDC, including 10% ripple (P-P) |
20 to 30 VDC, including 10% ripple (P-P) |
||||||
|
Power |
Normal | 2200 mW max. (30 V, 73.3 mA max.) | 2700 mW max. (30 V, 90 mA max.) | |||||
| Power saving (Eco) |
1700 mW max. (30 V, 56.7 mA max.) | 2200 mW max. (30 V, 73.3 mA max.) | ||||||
| Display power | Measured value display | 6 + 1/2-digit 7-segment LED (red) | ||||||
| Other displays | 2-color, 13-level bar LED display (red, green), indicators (red, green) | |||||||
|
Display range |
-199.999.9 to 199.999.9 | |||||||
| Display resolution | 0.1 μm 0.004 Mil | |||||||
| Sampling rate | 1000 times/sec. | |||||||
| Control input | Timing input | Input time: 2 ms min. | ||||||
| Preset input | Input time: 20 ms min. |
|||||||
|
Reset input | ||||||||
| Bank input | ||||||||
|
Control output |
HH | NPNopen collector,
Applicable current: 50 mA,Maximum applicable voltage40
V | — |
|||||
|
High | NPNopen
collector, Applicable current: 50 mA,Maximum applicable voltage40
V | |||||||
| Go | ||||||||
|
Low | ||||||||
| LL | NPNopen collector, Applicable current: 50
mA,Maximum applicable voltage40 V |
— | ||||||
| Analog output | — | 4 to 20 mA, maximum load
resistance: 350 Ω | ||||||
| Response time | hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s | |||||||
|
Environmental |
Ambient temperature |
-10 to +50°C (14 to 122°F)(No freezing) | -10 to +50°C (14 to 122°F) (GT2-71MCN/71MCP: -10 to +45°C (14 to 113°F) when expansion unit(s) is connected) (No freezing) | |||||
|
Relative humidity |
35 to 85% RH (No condensation) | |||||||
| Vibration | 10 to 55 Hz, 1.5 mm 0.06", double amplitude, 2 hours in each of X, Y, and Z directions | |||||||
| Materials | Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC |
|||||||
|
Power supply/I/O cable |
— | |||||||
| Weight | Approx. 140 g (including power cable) | Approx. 70 g | ||||||
| Accessories | Instruction manual, Cover seal | None |
Instruction manual, Cover seal |
None | Instruction manual, Cover seal | |||
|
*1 Precautions when the GT2-70 Series is
used with an expansion unit (excluding GT2-71D) | ||||||||
|
Model |
NPN | GT2-75N | GT2-76N | GT2-100N | GT2-E3N | ||
| PNP |
GT2-75P | GT2-76P | GT2-100P | GT2-E3P | |||
|
Mounting method |
Panel mount | Panel mount/Screw mounting
using optional |
Installed into GT2-100N/100P | ||||
| Type |
— | ||||||
| Main unit/Expansion unit *1 | Main unit | Expansion unit | 2 channels provided as
standard. Addition of expansion | Expansion unit (1 to 3 channels) | |||
| Power supply voltage *1 |
10 to 30 VDC, including 10% ripple (P-P) |
20 to 30 VDC, including 10% ripple (P-P) |
Supplied from GT2-100N/100P | ||||
|
Power |
Normal | 2200 mW max. (30 V, 73.3 mA max.) | 4500 mW max. (30 V, 150 mA max.) | 4200 mW max. (30 V, 140 mA max.)*2 | |||
| Power saving (Eco) | 1700 mW max. (30 V, 56.7 mA max.) | 3600 mW max. (30 V, 120 mA max.)*2 | 4000 mW max. (30 V, 133.3 mA max.) | ||||
| Display power | Measured value display | 6 + 1/2-digit 7-segment LED (red) | — | ||||
|
Other displays |
2-color, 13-level bar LED display (red, green), indicators (red, green) | ||||||
| Display range | -199.999.9 to 199.999.9 | ||||||
| Display resolution | 0.1 μm 0.004 Mil | ||||||
| Sampling rate | 1000 times/sec. | ||||||
| Control input | Timing input | Input time: 2 ms min. | |||||
| Preset input | Input time: 20 ms min. |
||||||
|
Reset input | |||||||
| Bank input | |||||||
|
Control output |
HH | NPNopen
collector, Applicable current: 50 mA,Maximum applicable voltage40
V | NPNopen
collector, Applicable current: 50 mA,Maximum applicable voltage40
V | ||||
| High | |||||||
| Go | |||||||
|
Low | |||||||
| LL | |||||||
|
Analog output |
— | ||||||
| Response time | hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s | ||||||
|
Environmental |
Ambient temperature |
-10 to +50°C (14 to 122°F) (No freezing) | |||||
|
Relative humidity |
35 to 85% RH (No condensation) | ||||||
| Vibration | 10 to 55 Hz, 1.5 mm 0.06", double amplitude, 2 hours in each of X, Y, and Z directions | 10 to 55 Hz, 0.15 mm 0.01"double amplitude, 2 hours in each of X, Y, and Z directions | 10 to 55 Hz, 1.5 mm 0.06", double amplitude, 2 hours in each of X, Y, and Z directions | ||||
| Materials | Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC | Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET | — |
||||
|
Power supply/I/O cable |
12-core connector connection (Connecting cable included) | Power supply: Terminal
block, | I/O: 30-pin connector (MIL standard) | ||||
| Weight | Approx. 140 g (including panel mounting bracket, protective front cover and power cable) |
Approx. 380 g | Approx. 80 g | ||||
| Accessories | Panel mounting bracket, protective front cover, power cable, instruction manual, cover seal | Panel mounting bracket, protective front cover, power cable, expansion cable | Instruction manual, panel mounting bracket | None |
|||
|
*1 Precautions when the GT2-70 Series is
used with an expansion unit (excluding GT2-71D) | |||||||
|
Model | GT2-71D |
|||
|
Type |
Installation type | DIN rail mount | ||
|
Main unit/expansion unit | Main unit | |||
|
Number of expandable units | Cannot be extended | |||
|
Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 |
|||
|
Display indicator | Power (green), alarm (red), pulse output (green), input (green) | |||
|
Pulse resolution | 0.1 μm 0.004 Mil, 0.5 μm 0.02 Mil, 1 μm 0.04 Mil, 10 μm 0.039 Mil (selectable) | |||
|
Power consumption | 1,600 mW or less (at 30 V: 53.3 mA or less) | |||
|
Minimum phase difference | 0.5 μs, 2.5 μs, 5 μs, 25 μs (selectable) | |||
|
Control input (origin return) |
No-voltage input (with contacts, without contacts), input time: 20 ms or more | |||
|
Output signal | 90° phase difference from the A, B, and Z phases; differential square wave (conforms to EIA-422) | |||
|
Output signal level | +5 V | |||
|
Environmentalresistance |
Operating ambient temperature | -10 to +50°C (no freezing) | ||
|
Operating ambient humidity | 35 to 85% RH (No condensation) | |||
|
Vibration resistance | 10 to 55 Hz, 1.5 mm 0.06" double amplitude for 2 hours in each of the X, Y, and Z directions | |||
|
Material |
Main unit case front cover |
Polycarbonate (PC) | ||
|
Weight | Approx. 110 g (including the power supply cable) |
|||
1-888-KEYENCE
(1-888-539-3623)