CMOS Multi-Function Analog Laser SensorIL series

DL-RB1A

BCD Output Unit

SPECIFICATIONS

Select Language

Model

DL-RB1A*1

Communication method

Synchronization between the transmitter and receiver

Transmission code

Baud rate

Indicator

Alarm indicator lamp (red), Power indicator lamp (green)

Sensor
connection
specifications

Number of
connectable
sensor units

Up to 8 units (including main unit)

BCD output specifications

I/O terminal

34-pin connector (MIL standard)

Control output

BCD output: 4 outputs (1 digit) × 6 digits, signed output, strobe output, alarm output, NPN open-collector output: 40 V, 20 mA or less, residual voltage: 1 V or less, positive logic/negative logic (switchable)

Control input

ID selection input: 4 inputs, data request input, no-voltage input (with contacts, without contacts); input time: 2 ms or more; short-circuit current: 1 mA

Rating

Power voltage

20 to 30 VDC, including ripple, Ripple (P-P): 10% max. Class 2 (Supplied via connected sensor amplifier)

Power consumption

27 mA max.

Environmental resistance

Operating temperature range

-10 to +55°C 14 to 131°F

Operating ambient humidity

35 to 85%RH (No condensation)

Vibration

10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours

Material

Case/Polycarbonate

Weight

Approx 46 g

*1 For connecting with sensor, please refer to the user's Manual