High-Speed, High-Accuracy CCD Laser Displacement Sensor

LK-G3000 series

Catalogs View Catalog

Sensor Head: Ultra Long Distance, Small spot LK-G502

LK-G502 - Sensor Head: Ultra Long Distance, Small spot

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking

Specifications

Model

LK-G502

Reference distance

Diffused reflection: 500 mm 19.69", Specular reflection: 497.5 mm 19.59"

Measuring range

Diffused reflection: -250 to +500 mm -9.84" to 19.69", Specular reflection: -249 to +498 mm -9.80" to 19.61"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. ø300 µm ø0.0118"

Linearity

±0.05 % of F.S. (±250 µm ±0.0098")*3*4 -250 to +250 mm -9.84" to +9.84"
High-accuracy range: ±0.02 % of F.S. (±100 µm ±0.0039") -250 to -50 mm -9.84" to -1.97"
Long range: ±0.1 % of F.S. (±500 µm ±0.0197") -250 to +500 mm -9.84" to +19.69" (F.S. = ±250 mm ±9.84")*5

Repeatability

2 µm 0.000079"*6

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±250 mm ±9.84")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 380 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes -230 mm -9.06" (NEAR side) to -250 mm -9.84" (NEAR side) for Diffused reflection.
When the sampling rate is 20 µs, the range becomes -230 mm -9.06" (NEAR side) to -249 mm -9.80" (NEAR side) for specular reflection.
When the sampling rate is 50 µs, the range becomes -125 mm -4.92" (NEAR side) to -250 mm -9.84" (NEAR side) for Diffused reflection.
When the sampling rate is 50 µs, the range becomes -125 mm -4.92" (NEAR side) to -249 mm -9.80" (NEAR side) for specular reflection.
*3 All are calculated at F.S. = ±250 mm ±9.84".
*4 "High accuracy range" and "long range" refer to the linearity when those ranges are used.
*5 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*6 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.

Data Sheet (PDF) Other Models