High-Speed, High-Accuracy CCD Laser Displacement Sensor

LK-G3000 series

Catalogs View Catalog

Sensor Head: Ultra Long Distance, Wide beam LK-G507

LK-G507 - Sensor Head: Ultra Long Distance, Wide beam

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking

Specifications

Model

LK-G507

Reference distance

Diffused reflection: 500 mm 19.69", Specular reflection: 497.5 mm 19.59"

Measuring range

Diffused reflection: -250 to +500 mm -9.84" to 19.69", Specular reflection: -249 to +498 mm -9.80" to 19.61"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. 300 x 9,500 µm 0.0118" x 0.3740"

Linearity

±0.05 % of F.S. (±250 µm ±0.0098")*3*4 -250 to +250 mm -9.84" to +9.84"
High-accuracy range: ±0.02 % of F.S. (±100 µm ±0.0039") -250 to -50 mm -9.84" to -1.97"
Long range: ±0.1 % of F.S. (±500 µm ±0.0197") -250 to +500 mm -9.84" to +19.69" (F.S. = ±250 mm ±9.84")*5

Repeatability

2 µm 0.000079"*6

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±250 mm ±9.84")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 380 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes -230 mm -9.06" (NEAR side) to -250 mm -9.84" (NEAR side) for Diffused reflection.
When the sampling rate is 20 µs, the range becomes -230 mm -9.06" (NEAR side) to -249 mm -9.80" (NEAR side) for specular reflection.
When the sampling rate is 50 µs, the range becomes -125 mm -4.92" (NEAR side) to -250 mm -9.84" (NEAR side) for Diffused reflection.
When the sampling rate is 50 µs, the range becomes -125 mm -4.92" (NEAR side) to -249 mm -9.80" (NEAR side) for specular reflection.
*3 All are calculated at F.S. = ±250 mm ±9.84".
*4 "High accuracy range" and "long range" refer to the linearity when those ranges are used.
*5 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*6 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.

Data Sheet (PDF) Other Models