Model

LK-G10

LK-G15

LK-G32

LK-G37

Reference distance

10 mm 0.39"

30 mm 1.18"(Diffuse reflection), 23.5 mm 0.93"(Specular reflection)

Measuring range

±1 mm ±0.04"

±5 mm ±0.2"(Diffuse reflection),±4.5 mm ±0.18"(Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

650 nm (visible light)

Laser Class

Class II (FDA (CDRH) Part 1040.10),
Class 1 (IEC 60825-1)

Class II (FDA (CDRH) Part 1040.10), Class 2 (IEC 60825-1)

Output

0.3 mW

0.95 mW

Spot diameter (at reference distance)

Approx. φ20 μm φ0.79 Mil

Approx. 20 x 500 μm
0.79 x 19.69 Mil

Approx. φ30 μm φ1.18 Mil

Approx. 30 x 850 μm
1.18 x 33.46 Mil

Linearity *1

±0.03% of F.S. (F.S.= ±1 mm ±0.04")

±0.05% of F.S. (F.S.= ±5 mm ±0.2")

Repeatability *2

0.02 μm 0.0008 Mil
(0.01 μm 0.0004 Mil)

0.05 μm *3 0.002 Mil

Sampling time

20/50/100/200/500/1000 μs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights, Within the measurement area: Orange lights, Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C
(F.S.= ±1 mm ±0.04")

0.01% of F.S./°C
(F.S.= ±5 mm ±0.2")

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 10000 lux max.

Ambient temperature

0 to 50°C (32 to 122°F)

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, double amplitude 1.5 mm 0.06"; two hours in each direction of X, Y, and Z

Material

Aluminum die-cast

Weight (including the cable)

Approx. 190 g

Approx. 280 g

*1 The value is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
*2 The value is obtained by measuring KEYENCE’s standard(SUS) with 4096 times of averaging at the reference distance. The value in parenthesis is the typical repeatability obtained by measuring the
target with 16384.
*3 Consult your nearest KEYENCE representative for the Class IIIa type with increased repeatability.

Sensor head

Model

LK-G82

LK-G87

LK-G152

LK-G157

Reference distance

80 mm 3.15"(Diffuse reflection),75.2 mm 2.96"(Specular reflection)

150 mm 5.91"(Diffuse reflection),147.5 mm 5.81"(Specular reflection)

Measuring range

±15 mm ±0.59"(Diffuse reflection),±14 mm ±0.55"(Specular reflection)

±40 mm ±1.57"(Diffuse reflection),±39 mm ±1.54"(Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

650 nm (visible light)

Laser Class

Class II (FDA (CDRH) Part 1040.10), Class 2 (IEC 60825-1)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. φ70 μm φ2.76 Mil

Approx. 70 x 1100 μm
2.76 x 43.31 Mil

Approx. φ120 μm φ4.72 Mil

Approx. 120 x 1700 μm
4.72 x 66.93 Mil

Linearity *1

±0.05% of F.S. (F.S.= ±15 mm ±0.59")

±0.05% of F.S. (F.S.= ±40 mm ±1.57")

Repeatability *2

0.2 μm *3 0.008 Mil

0.5 μm *3 0.02 Mil

Sampling time

20/50/100/200/500/1000 μs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights, Within the measurement area: Orange lights, Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C
(F.S.= ±15 mm ±0.59")

0.01% of F.S./°C
(F.S.= ±40 mm ±1.57")

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 10000 lux max.

Incandescent lamp or fluorescent
lamp:5000 lux max.

Ambient temperature

0 to 50°C (32 to 122°F)

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, double amplitude 1.5 mm 0.06"; two hours in each direction of X, Y, and Z

Material

Aluminum die-cast

Weight (including the cable)

Approx. 380 g

Approx. 290 g

*1 The value is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
*2 The value is obtained by measuring KEYENCE’s standard(SUS) with 4096 times of averaging at the reference distance. The value in parenthesis is the typical repeatability obtained by measuring the
target with 16384.
*3 Consult your nearest KEYENCE representative for the Class IIIa type with increased repeatability.

Sensor head

Model

LK-G402

LK-G407

LK-G502

LK-G507

Reference distance

400 mm 15.75"(Diffuse reflection),398 mm 15.67"(Specular reflection)

500 mm 19.69"(Diffuse reflection),497.5 mm 19.59"(Specular reflection)

Measuring range

±100 mm ±3.94"(Diffuse reflection),±99 mm ±3.90"(Specular reflection)

-250 to +500 mm -9.84" to 19.69"(Diffuse reflection),-249 to +498 mm -9.80" to 19.61"(Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA (CDRH) Part 1040.10), Class 2 (IEC 60825-1)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. φ290 μm φ11.42 Mil

Approx. 290 x 8300 μm 11.42 x 326.77 Mil

Approx. φ300 μm φ11.81 Mil

Approx. 300 x 9500 μm 11.81 x 374.02 Mil

Linearity *1

±0.05% of F.S.(F.S.= ±100 mm ±3.94")

±0.05% of F.S. ( ±250 μm ±9.84 Mil) *3*4 -250 to +250 mm -9.84" to +9.84"
<high-accuracy range> ±0.02% of F.S. ( ±100 μm ±3.93 Mil)
-250 to -50 mm -9.84" to -1.97"
<long range> ±0.1% of F.S. ( ±500 μm ±19.7 Mil)
-250 to +500 mm -9.84" to +19.69" (F.S. = ±250 mm ±9.84")

Repeatability *2

2 μm 0.08 Mil

Sampling time

20/50/100/200/500/1000 μs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./˚C (F.S.= ±100 mm ±3.94")

0.01% of F.S./˚C (F.S.= ±250 mm ±9.84")

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 5000 lux max.

Ambient temperature

0 to 50°C (32 to 122°F)

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, double amplitude 1.5 mm 0.06"; two hours in each direction of X, Y, and Z

Material

Aluminum die-cast

Weight (including the cable)

Approx. 380 g

*1 The value is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
*2 The value is obtained by measuring KEYENCE’s standard(SUS) with 4096 times of averaging at the reference distance. The value in parenthesis is the typical repeatability obtained by measuring the
target with 16384.
*3 All are calculated at F.S. = (±250 mm ±9.84" ).
*4 “High accuracy range” and “long range” refer to the linearity when those ranges are used.

Controller

Model

NPN

LK-G3001V

LK-G3001

PNP

LK-G3001PV

LK-G3001P

Type

All-in-one model

Separate monitor model *3

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 μm 0.0004 Mil

Display range

±9999.99 mm to ±9999.99 μm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing/Reset/Auto-zero input

For OUT1, non-voltage or voltage input *1

Laser remote interlock input

Non-voltage input *1

Comparator output

For OUT1, NPN open-collector output *2

Alarm output

For OUT1, NPN open-collector output *2 (N.C.)

Expansion connector

Timing/Reset/Auto-zero input

For OUT2, non-voltage or voltage input *1

Program switching input

Non-voltage or voltage input *1 x 3 inputs

Laser-Off input

For Head A/Head B, non-voltage or voltage input *1

Comparator output

For OUT2, NPN open-collector output *2

Alarm output

For OUT2, NPN open-collector output *2(N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output *2

Strobe output

NPN open-collector output *2

Binary selector output

Binary selector input

Non-voltage or voltage input *1.

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Power supply voltage

24 VDC±10%, Ripple: 10% (P to P) or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Ambient temperature

0 to 50°C (32 to 122°F)

Relative humidity

35 to 85%, No condensation

Weight

Approx. 480 g

Approx. 370 g

*1 (NPN model) The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current. (PNP model) The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFF
current.
*2 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 0.5 V max. The rating of the PNP open collector: 50 mA max. (30 V max.), residual voltage of 0.5 V max.
*3 LK-G3001(P) can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

Extension cable(Cable between the head and controller)

Model

LK-GC2

LK-GC5

LK-GC10

LK-GC20

LK-GC30

Cable length

2 m 6.6'

5 m 16.4'

10 m 32.8'

20 m 65.6'

30 m 98.4'

Weight

Approx. 200 g

Approx. 400 g

Approx. 750 g

Approx. 1400 g

Approx. 2000 g

Extension cable(Cable for display panel)

Model

OP-51654

OP-51655

OP-51656

Cable length

0.3 m 0.98'

3 m 9.8'

10 m 32.8'