Ultra High-Speed/High-Accuracy Laser Displacement SensorLK-G5000 series

LK-CC100

Communication Unit

SPECIFICATIONS

Select Language

Model

LK-CC100

Type

CC-Link communication unit dedicated to LK-G5000 Series

Network connection

Supported CCLink version

Ver. 1.10 (Extended cyclic setting: Single) Ver. 2.00 (Extended cyclic setting: Double or more)*1*2

Master unit

CLPA-certified master unit (CC-Link Ver. 2.00/Ver. 1.10)

No. of occupied stations

1 to 4

Communication speed

156kbps、625kbps、2.5Mbps、5Mbps、10Mbps

Connection cable

Dedicated CC-Link cable supporting Ver. 1.10 (Shielded 3-core twisted-pair cable: OP-79426, OP-79427)

Maximum total cable extension length

156kbps…1200m、 625kbps…900m、 2.5Mbps…400m、 5Mbps…160m、 10Mbps…100m

Station type

Remote device station

Rating

Power voltage

24 VDC ±10 % (supplied from controller)

Current consumption.

200mA or less

Environmental resistance

Operating temperature range

When one or less head expansion unit is connected: 0 to 50°C 32 to 122°F.
When two or more head expansion units are connected: 0 to 40°C 32 to 104°F.

Operating ambient humidity

35 to 85% RH (No condensation)

Weight

Approx 300 g

*1 The LK-G5000 Series supports the "extended cyclic transmission" and "station-to-station cable length relaxation" of CC-Link Ver. 2.00.
*2 CC-Link is a registered trademark of Mitsubishi Electric Corporation.