High-speed, High-accuracy CCD Laser Displacement Sensor
| Model | Sensor head |
LK-011 | LK-031 | LK-036 | LK-081 | LK-086 | LK-503 | ||
|
Controller |
LK-3101 |
LK-2001 |
LK-2011 |
LK-2101 |
LK-2111 |
LK-2503 | |||
| Type |
Compact high-accuracy Sensor head |
High-precision Sensor head |
Standard Sensor head |
Long-distance *4 Sensor head | |||||
|
Measurement mode |
Normal,mirror surface |
— | High-precision mode, Long-range mode | ||||||
| Reference distance | 10 mm0.39"(Normal),7.0 mm0.28"(mirror surface) | 30 mm 1.18" |
80 mm 3.15" |
350 mm 13.78"(High-precision mode), 500 mm 19.69"(Long-range mode) | |||||
| Measuring range | ±1 mm±0.04"(Normal),±0.9 mm±0.04"(mirror surface) | ±5 mm ±0.20" |
±15 mm ±0.59" |
±100 mm ±3.94"(High-precision mode), ±250 mm ±9.84"(Long-range mode) | |||||
|
Light source | Type | Visible red semiconductor laser | |||||||
|
Wavelength | 670 nm |
690 nm | |||||||
|
Laser |
FDA (CDRH) 21CFR Part 1040.10 |
Class II Laser Product | |||||||
| IEC 60825-1 | Class 2 Laser Product |
||||||||
|
Output | 0.95 mW | ||||||||
|
Spot diameter |
Approx. 20 μm | Approx. 30
μm | Approx. 30 x | Approx. 70
μm | Approx. 70 x | Approx. 0.7 mm 0.03"(High-precision mode), Approx. 0.3 mm 0.01"(Long-range mode) | |||
| Linearity |
±0.25% of F.S. *1 |
±0.1% of F.S. *1 | |||||||
| Resolution |
0.1 μm *2 0.004 Mil |
1 μm *2 0.039 Mil |
3 μm *2 0.12 Mil | 10 μm *2 0.39 Mil(High-precision mode), 50 μm *2 1.97 Mil(Long-range mode) | |||||
| Analog output | Voltage output | ±10 V (±9
V) |
±5 V |
±5 V | ±10
V(10 μm 0.39 Mil/mV)
*3(High-precision mode), | ||||
| Impedance | 100 Ω | ||||||||
| Current output | 4 to 20 mA (Applicable load: 350 Ωmax.) | ||||||||
| Alarm output | NPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max. | ||||||||
| Sampling cycle | 128/256/512/2,048
μs |
512 μs | 1024 μs | ||||||
|
Other functions |
AUTO ZERO, Response selection, Shift/Span adjustment, Holding output in alarm condition | ||||||||
| Power supply | 24 VDC ±10%, Ripple: 10% (P to P) or less | ||||||||
| Current consumption |
400 mA max. | ||||||||
|
Temperature | Sensor head |
0.04% of F.S./°C | 0.01% of F.S./°C |
0.02% of F.S./°C | |||||
|
Controller | 0.005% of F.S./°C | 0.01% of F.S./°C | |||||||
| Enclosure rating | IP64 |
IP67 | |||||||
| Ambient light | Incandescent or fl uorescent lamp: 10000 lux max. | ||||||||
| Ambient temperature | 0 to 50°C (32 to 122°F) | ||||||||
| Relative humidity | 35 to 85%, No condensation | ||||||||
| Housing | Aluminum die-cast | ||||||||
|
Weight |
Sensor head |
Approx. 80 g | Approx. 260 g | Approx. 385 g | Approx. 700 g | ||||
| Controller | Approx. 515 g | ||||||||
| *1
Linearity was obtained using KEYENCE’s standard target
(Zirconia block gauge: LK-031/036, LK-081/086, LK-011, White
ceramic block gauge: LK-503). |
|||||||||
1-888-KEYENCE
(1-888-539-3623)