Surface Scanning Laser Confocal Displacement MeterLT-9000 series

LT-9001HSO(5655)

Controller, Not Subject to Export Control, with Camera Function, English Manual

SPECIFICATIONS

Select Language

Model

LT-9001HSO(5655)

Measuring unit compatibility

Measuring units are interchangeable without factory recalibration.

Display

Minimumdisplayable unit

0.1 µm *1

Display range

±9999.99 µm

Microscopefunction

Display cycle

10 times/sec.*2

Terminal block

Analog output

±10 V x 2 outputs, output impedance: 100 Ω

Timing input

Non-voltage input

Reset input

Auto-zero input

Monitor dedicated power supply

24 VDC*3

Control I/O

Judgment mode

3-step limits output

For OUT1 and OUT2, and NPN open collector output*4

Binary mode

Binary output

Measured data output (21 bits), OUT1/OUT2/PROFILE selectable
NPN open collector output*4

Strobe output

NPN open collector output*4

Binary selector output

Binary selection input

Non-voltage input*4

Stability output

NPN open collector output

Laser remote input

Non-voltage input

Program switching input

Non-voltage input x 3 inputs

RS-232C interface

Measured data output and control I/O (Selectable up to baud rate 115200 bps.)

Video output

NTSC compliant (PIN connector)

Main functions

Displacement mode

Distance measurement, Transparent object thickness
measurement, Surface selection, Dark-out, Mask, Trend graph
display, and Scan width/interval change*5

Profile mode

*5

Common

Light intensity accumulation, Microscope (LT-9501H, LT-9501HSO (5654) only), Tolerance
judgment, 8-program registration, Calibration, Averaging, Hold modes, Auto-zero, and
interface language selection

Rating

Power voltage

100 to 240 VAC ±10% 50/60 Hz

Power consumption

110VA or less

Environmental resistance

Overvoltage category

II

Pollution degree

2

Operating temperature range

0 to +35°C 32°F to 95°F

Operating ambient humidity

35 to 85% RH (No condensation)

Weight

Approx 2.4 kg

*1 Display changes every ±0.3 µm.
*2 Varies depending on the setting
*3 Dedicated power supply for the monitor specified by KEYENCE.
*4 Select either the Limits mode or the Binary mode.
*5 Select either the Distance mode or the Profile mode. (Distance mode is only available with the LT-9501HSO (5654)
and LT-9001HSO (5655).)
The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V.
The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower.

Tips of Measurement

  • General Catalog Request
  • Trade Shows and Exhibitions
  • eNews Subscribe

Measurement Sensors