| Model | RD-50E |
RD-50R | |||
| Measurement function | DC voltage measurement, DC current measurement | ||||
| A/D converting system | Successive comparison | ||||
| Measuring range | ±5 VDC, ±10 VDC, 4 to 20 mA DC (selectable) |
||||
|
Display range |
-19,999 to +39,999 | ||||
| Measuring accuracy | ±0.03% of F.S.
(at ±5 VDC range), ±0.03% of F.S. (at ±10 VDC
range) | ||||
|
Input | Impedance | 1 MΩ (for voltage input), 350 Ω (for current input) | |||
| System | Single-ended | ||||
| Number of inputs | 2 |
||||
|
Sampling rate |
2000/s | ||||
| Display rate | 20/s | ||||
| Display character | 7-segment 3-color LED (character height: 15.24 mm 0.60") | ||||
| Range-over alarm | FFFF is displayed | ||||
| Control input | Synchronous,
Hold-reset, Auto-zero, External setting, | ||||
| Control output*1 |
Tolerance setting |
4 steps x 8 programmable setups (selectable) | |||
|
Signal | 5 x NPN (HH, HI, GO, LO, LL): 100 mA max. (40 V max.) | ||||
| Response time | 1 ms (when average number 1) | ||||
| Off-delay time | 60 ms (ON/OFF selectable) | ||||
| Analog voltage output | Voltage | ±10 VDC | |||
| Impedance | 100 Ω | ||||
| Response time | 1 ms (when average number 1) *2 | ||||
| Interface |
Control input by NPN open-collector or | Data output and control input through RS-232C | |||
| Rating | Power supply |
24 VDC ±10% | |||
| Current consumption | 270 mA max. | ||||
|
Ambient temperature |
0 to 50°C (32 to 122°F) |
||||
|
Relative humidity |
35 to 85%, No condensation | ||||
| Weight | Approx. 700 g (excluding fi ttings) | ||||
|
Major functions |
MDL, digital fi lter, auto-zero, offset, input, data
processing (10 modes), | ||||
| *1 NPN output
can easily be converted to PNP output by connecting the optional
OP-5148 PNP output converter. | |||||