Separate Amplifier Type Air Flow Sensor

FD-V40 series

Catalogs View Catalog

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Amplifier Unit, Panel Mount Type, NPN FD-V45

FD-V45 - Amplifier Unit, Panel Mount Type, NPN

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Specifications

Model

FD-V45

Type

Panelmount

Output

NPN output

Current consumption.

At 12 V

Normal

1500 mW (125 mA) or less

Eco mode

1320 mW (110 mA) or less

At 24 V

Normal

2000 mW (83 mA) or less

Eco mode

1700 mW (70 mA) or less

Detection range

FD-A10: 0.3 to 10L/min (std)
FD-A50: 1.5 to 50L/min (std)
FD-A100: 3 to 100L/min (std)

Display power

Dual row display with 3-digit 7-segment LED (upper row: red, lower row: green), display update cycle: 5 times/sec.

Operation status indicators

Red LED × 2 (control output 1 and control output 2), green LED (integration display)

Resolution

FD-A10: 0.01L
FD-A50: 0.1L
FD-A100: 0.1L

Hysteresis

Variable

Response time (chatter prevention feature)

HSP (5 ms), 0.02, 0.1, 1, 5 (selectable)

Integrated sampling cycle

30ms

Integrated data memory

Writes to memory once every minute

Accumulated flow unit

FD-A10 : Selectable from 0.01, 0.1, 1, 10, 100 (ℓ)
FD-A50 : Selectable from 0.1, 1, 10, 100, 1000 (ℓ)
FD-A100 : Selectable from 0.1, 1, 10, 100, 1000 (ℓ)

Integration reset input

Input time: 20 ms or more (switchable with analog output)

Control output/integration pulse output

Maximum open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)

Analog output

4 to 20 mA, Maximum load resistance 260 Ω

Repetition accuracy

±0.5% of F.S. or less (at the operating ambient temperature of 25°C 77°F)

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z axis

Material

Housing material: Polycarbonate, Key top: Silicon rubber

Accessories

Panel mounting bracket, front protection cover, power cable, Instruction Manual

Weight

Approx. 85 g (including panel mount bracket, front protection cover and power cable)

Data Sheet (PDF) Other Models