Two-color Digital Display Pressure SensorAP-30 series

AP-32KP

Main Unit, Positive-pressure Type, 100 kPa, PNP

SPECIFICATIONS

Select Language

Model

AP-32KP

Type

Positive pressure , Analog [cannot be used within Japan according to the Measurement Act]

Output

PNP output

Rated pressure

0 to 14.50 PSI

Type of pressure

Gauge pressure, air or non-corrosive gases

Fluid type

Air or non-corrosive gases

Display resolution

0.02 Psi, 0.1 kPa,
0.001 kgf / cm2, 0.001 bar

Display range

-15% to +110% of F.S.

Response time (chatterprevention function)

2.5/5/100/500 ms (selectable)

Display power

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43")

I/O

Control output

PNP open-collector 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable)

Analog output

1 to 5 V (Load impedance: 47 kΩ min.)

Zero-shift input

Display

±1% max. (of F.S.) of detecting pressure at 25°C 77°F (0 to 50°C 32 to 122°F)

Control output hysteresis

Variable (when hysteresis mode is selected), 0.5% of F.S. in standard mode

Rating

Power voltage

12 to 24 VDC ±10 %

Current consumption

50 mA (at 24 V) or less, 90 mA (at 12 V) or less

Environmental resistance

Pressure resistance

4.9 bar (490 kPa)

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable

Accessories

Mounting bracket A, mounting bracket B, hexagon socket head cap plug

Weight

Approx. 120 g