Separate Amplifier Type Pressure SensorAP-40 series

AP-40

Amplifier Unit NPN

SPECIFICATIONS

Select Language

Model

AP-40

Output

NPN output

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/sec.

Applicable sensor head

AP-41, AP-43, AP-44

Detectable pressure range

-15% to +110% of F.S.

Display resolution

0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar [AP-41]
0.001 MPa, 0.01 kgf/cm2, 0.2 Psi, 0.01 bar [AP-43]
0.2 kPa, 2 mmHg, 0.1 inchHg, 0.002 bar [AP-44]

Response time (chattering
prevention function)

2.5/5/100/500 ms

Control output

NPN: 100 mA max. (40 V max.),
Residual voltage: 1 V max. 2-output (N.O./N.C. selectable)

Analog voltage output

1 to 5 V

Temperature fluctuation for display

±1.0% max. of F.S.

Temperature fluctuation for analog output

±2.0% max. of F.S.

Mounting

With supplied mounting bracket (2 types) or optional panel mounting bracket*1

Current consumption

105 mA (12 V), 55 mA (24 V) (including sensor head)

Power supply

12 to 24 VDC ±10%, Ripple (p-p): 10% max.

Ambient temperature

0 to 50°C (32 to 122°F), No condensation

Relative humidity

35 to 85%, No condensation

Shock

100 m/s2 in X, Y, and Z directions, 3 times respectively

Vibration

10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively

Material

Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, Cable: Oil-proof cabtyre cable

Weight

80 g (including 2 m 6.6' cable) (28 g without cable)

*1 Two types of panel mounting brackets are available: OP-31357 (black) and OP-32908 (gray).

  • General Catalog Request