Ultra-compact Digital Pressure Sensor
|
Model |
NPN | AP-C30K | AP-C31K | AP-C33K | ||
| PNP |
AP-C30KP | AP-C31KP | AP-C33KP | |||
|
Type | Multi range | Negative pressure | Positive pressure | |||
|
Rated pressure range |
Negative pressure mode:0 to -29.9inchHg,Positive pressure mode:0 to 29.5inchHg,Compound pressure mode:+29.9 to -29.9inchHg | 0 to -29.9 inchHg | 0 to 145 PSI | |||
|
Proof pressure |
72.5 PSI | 217.5 PSI |
||||
|
Fluid type | Air or non-corrosive gases | |||||
| Pressure type | Gauge pressure | |||||
| Power supply voltage |
12 to 24 VDC ±10% with ripple (p-p) of 10% max. | |||||
|
Power consumption |
12 V | Normal | 720 mW (60 mA) max. | |||
| Economical mode |
480 mW (40 mA) max. | |||||
| 24 V | Normal | 960 mW (40 mA) max. | ||||
| Economical mode |
720 mW (30 mA) max. | |||||
| Display | 3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") Display cycle: 10 times/s | |||||
| Set and display range *1 | -10 to +110% of F.S. | -15 to +110% of F.S. | ||||
| Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) | |||||
|
Resolution | Negative pressure:0.1 inchHg,Positive pressure:0.1 inchHg,Compound pressure:0.1 inchHg | 0.1 inchHg(Normal mode),0.01 inchHg(Focus mode) | 0.2 PSI(Normal mode),0.02 PSI(Focus mode) | |||
| Repetitive precision | ±0.2% of F.S. | |||||
| Hysteresis *2 | Variable (Standard: 0.5% of F.S.) | |||||
| Display temperature characteristic |
±1% of F.S. max. | |||||
| Response time (chattering prevention function) |
2.5, 5, 100, or 500 ms (selectable) |
|||||
|
Control output |
NPN open collector 100 mA max. (40 V) residual voltage 1 V max., 2 outputs (N.O. /N.C. selectable) | |||||
| Analog output | 1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) | |||||
| Zero-shift input | Non-voltage input (contact or SSR) with input time of 2 ms or more. (or analog output selectable) | |||||
| Ambient temperature | 0 to 50°C (32 to 122°F), No condensation | |||||
| Relative humidity | 35 to 85%, No condensation | |||||
| Vibration resistance | 10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively |
|||||
|
Pressure port |
NPT 1/8 180° rotation | |||||
| Material | Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting | |||||
| Weight | Approx. 30 g (without cable) Approx. 85 g (with 2-m 6.6' cable) |
|||||
|
Accessory | Power supply cord (2-m 6.6' cable with connector) | Power supply cord (2-m 6.6' cable with connector),Unit seal | ||||
| *1 The focus
range applies while in focus mode
only. | ||||||
1-888-KEYENCE
(1-888-539-3623)