Digital Pressure Sensor with 2-Color DisplayAP-C40 series

AP-C40WP

Amplifier Unit PNP

SPECIFICATIONS

Select Language

Model

AP-C40WP

Output

PNP output

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44

Display power

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") Display cycle: 10 times/s

Set and display range

-15 to +110% of F.S. *1

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Resolution

Standard mode

AP-41M

0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar

AP-41

AP-43

0.001 mPa, 0.01 kgf/cm2, 0.01 bar

AP-44

0.1 kPa, 1 mmHg, 0.1 inchHg, 0.02 psi, 0.001 bar

AP-48

0.1 kPa, 0.001 kgf/cm2, 0.02 psi, 0.001 bar

Focus mode

AP-41M

0.01 kPa, 0.1 mmHg, 0.01 inchHg, 0.002 psi, 0.1 mbar

AP-41

AP-43

0.1 kPa, 0.001 kgf/cm2, 0.02 psi, 0.001 bar

AP-44

0.02 kPa, 0.2 mmHg, 0.01 inchHg, 0.004 psi, 0.2 mbar

AP-48

0.02 kPa, 0.2 kgf/cm2, 0.004 psi, 0.2 mbar

Hysteresis

Variable (Standard: 0.5% of FS; high-resolution/focus mode: 0.1% of F.S.)

Response time
(chattering prevention function)

1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) *2

I/O

Control output

PNP open collector 100 mA max. (at 30 V or below) *3 with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

Display temperature characteristic

±1% of F.S. or less

I/O

Analog output (selectable)

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)*4

Zero-shift input (selectable)

Input time: 2 ms or more (or analog output selectable)

Rating

Power voltage

12 to 24 VDC ±10% with ripple (p-p) of 10% max.

Power consumption

At 12 V

Normal

960 mW (80mA) or less

Eco mode

660 mW (55mA) or less

At 24 V

Normal

1440 mW (60mA) or less

Eco mode

1080 mW (45mA) or less

Ambient temperature

0 to 50°C 32 to 122°F, no freezing

Relative humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate

Accessories

Power supply code (2-m 6.6' cable with connector), head connector, and unit seal

Weight

Approx. 74 g (with 2-m 6.6' cable)

*1 The focus range applies while in focus mode only.
*2 A response time of 100 or 500 ms applies if the AP-47 is used.
*3 The maximum current is 20 mA if the AP-V42W (P) is installed as an expansion unit.
*4 Only the AP-V41AW (P) (Master) and AP-C40W (P) apply.

  • General Catalog Request
  • Trade Shows and Exhibitions
  • eNews Subscribe