Digital Pressure Sensor with 2-Color Display

AP-C40 series

Select Language

Model

AP-41M

AP-41

AP-43

AP-44

Type of pressure

Gage pressure

Rated pressure

0 to -101.3kPa

0 to +1.000MPa

+101.3 to -101.3kPa

Pressure resistance

500 kPa

1.5 MPa

500 kPa

Fluid type

Air or non-corrosive gases

Temperature characteristics

±2% of F.S. max.

Pressure port

M3 male screw

M5 male screw

Display temperature characteristic

±2% of F.S. max.

Environmental resistance

Operating temperature range

0 to 50°C 32 to 122°F, no freezing

Operating ambient humidity

35 to 85%RH (no condensation)

Shock resistance

1000 m/s2 in X, Y, and Z directions, 10 times respectively

Vibration

10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 4 hours respectively

Material

Housing: PBT, Screw: Stainless steel

Weight

4.8 g (without cable)
67.8 g (with 3-m cable)

7 g (without cable)
70 g (with 3-m cable)

Model

NPN

AP-C40W

PNP

AP-C40WP

Display power

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") Display cycle: 10 times/s

Set and display range

-15 to +110% of F.S. *1

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Resolution

Standard mode

AP-41M

0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar

AP-41

AP-43

0.001 MPa, 0.01 kgf/cm2, 0.01 bar

AP-44

0.1 kPa, 1 mmHg, 0.1 inchHg, 0.02 psi, 0.001 bar

AP-48

0.1 kPa, 0.001 kgf/cm2, 0.02 psi, 0.001 bar

Focus mode

AP-41M

0.01 kPa, 0.1 mmHg, 0.01 inchHg, 0.002 psi, 0.1 mbar

AP-41

AP-43

0.1 kPa, 0.001 kgf/cm2, 0.02 psi, 0.001 bar

AP-44

0.02 kPa, 0.2 mmHg, 0.2 inchHg, 0.004 psi, 0.2 mbar

AP-48

0.02 kPa, 0.2 kgf/cm2, 0.004 psi, 0.2 mbar

Hysteresis

Variable (Standard: 0.5% of FS; high-resolution/focus mode: 0.1% of F.S.)

Response time
(chattering prevention function)

1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) *2

Control output

NPN

NPN open collector 100 mA max. (at 40 V or below) *3 with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

PNP

PNP open collector 100 mA max. (at 30 V or below) *3 with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

I/O

Analog output (selectable)

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)*4

Zero-shift input (selectable)

Input time: 2 ms or more (or analog output selectable)

Display temperature characteristic

±1% of F.S. or less

Rating

Power voltage

12 to 24 VDC ±10% with ripple (p-p) of 10% max.

Power consumption

At 12 V

Normal

780 mW (65mA) max./960 mW (80mA)max.

960 mW (80mA) or less

Eco mode

540 mW (45mA) or less

660 mW (55mA) or less

At 24 V

Normal

1080 mW (45mA) or less

1440 mW (60mA) or less

Eco mode

840 mW (35mA) or less

1080 mW (45mA) or less

Environmental resistance

Operating temperature range

0 to 50°C 32 to 122°F, no freezing

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate

Accessories

Power supply code (2-m 6.6' cable with connector), head connector, and unit seal

Weight

Approx. 74 g (with 2-m 6.6' cable)

*1 The focus range applies while in focus mode only.
*2 A response time of 100 or 500 ms applies if the AP-47 is used.
*3 The maximum current is 20 mA if the AP-V42W (P) is installed as an expansion unit.
*4 Only the AP-V41AW (P) (Master) and AP-C40W (P) apply.

Latest / Most Downloaded

    • General Catalog Request
    • Trade Shows and Exhibitions
    • eNews Subscribe

    Process Controls / Process Sensors