Network Compatible Pressure Sensor

AP-N series

Select Language

Sensor heads (Detection components)

Model

AP-41M

AP-41

AP-43

AP-44

AP-48

Application

Gauge pressure

Differential pressure

Type

Negative pressure

Positive pressure

Compound pressure

Rated pressure

0 to -101.3 kPa

0 to 1 Mpa

+101.3 to -101.3 kPa

-101.3 to +101.3 kPa

Fluid type

Air, non-corrosive gasses

Temperature characteristic

±2% of F.S. (When the temperature varies from 25°C 77°F)

Pressure port

M3 male threaded

M5 male threaded

R1/8

Environmental resistance

Pressure resistance

500 kPa

1.5 MPa

500 kPa

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 4 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 10 times in each of X, Y and Z directions, total of 60 times

Material

Case: PBT, Screw: SUS303, Cable: PVC

Weight

Approx. 68 g (including cable)

Approx. 70 g (including cable)

Approx. 98 g (including cable)

Sensor amplifiers (Display devices)

Model

AP-N10

AP-N10D

Type

Single output type

Dual output type

Connected heads

AP-41M, AP-41, AP-43, AP-44, AP-48

Display resolution

Standard mode

0.1 kPa (AP-41M/41/44/48), 0.001 MPa (AP-43)

High resolution mode

0.01 kPa (AP-41M/41/44/48), 0.1 kPa (AP-43)

Configuration/Display range

-15 to +110% of F.S.

Repeatability

±0.2% of F.S.

Display temperature characteristic

±1% of F.S. (When the temperature varies from 25°C 77°F)

Response time (Chattering prevention function)

1 ms / 2.5 ms / 5 ms / 100 ms / 500 ms / 1000 ms / 5000 ms selectable

Power voltage

12 to 24 VDC ±10% Ripple (P-P) 10% max. Class2

Power
consumption

Normal

770 mW or less (at 24 V, 32 mA or less / at 12 V, 54 mA or less)

Eco Mode

560 mW or less (at 24 V, 23 mA or less / at 12 V, 37 mA or less)

Expansion units

Max. 16 units (Dual output type is counted as 2 units.)*1

Control output(s)

1*2

2*2

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Main unit and cover: Polycarbonate

Weight

Approx. 20 g

*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers.
*2 Number of outputs when connected to the communication unit NU Series. There are no control output wires.
*3 11 to 16 units connected: 0 to +45 °C 32 to 113 °F (When the sensor amplifier is installed on DIN rail on a metal plate)

  • General Catalog Request
  • Trade Shows and Exhibitions
  • eNews Subscribe

Process Controls / Process Sensors