GP-M seriesHeavy Duty Type Digital Pressure Sensors

GP-M010

Main Unit, Positive-pressure Type, 1 MPa

SPECIFICATIONS

Select Language

Model

GP-M010

Rated pressure

-14.5 to +145.0 PSI
(-0.1 to +1 MPa)

Possible display range

-30.5 to +161.0 PSI
(-0.210 to +1.110 MPa)

Zero-cut pressure value

±0.5% of F.S.

Pressure resistance

580 PSI (4 MPa)

Burst pressure

2175 PSI (15 MPa)

Display resolution

kPa

None

MPa

0.001

PSI

0.1

bar

0.01

kgf/cm2

Display resolution

0.001 MPa (0.01 bar)

Fluid type

Gas or liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C 50°F

Connection port

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Detection fluid temperature

-20 to +100°C -4°F to +212°F (no freezing/condensation)*3

Rating

Power voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption.

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display power

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis

During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)

Response

Control output

Selectable from 3 to 5000 ms

Analog output

As above + 2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmental resistance

Operating temperature range

-20 to +80°C -4°F to +176°F (no freezing/condensation)

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)

Shock resistance

IEC60068-2-27 50 G (11 ms, 3 times for each of X, Y and Z axis)

Enclosure rating

IP67

Material

Liquid end materials

Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Material properties

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx 150 g

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.
*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω

For visitors who viewed this page