Heavy Duty Type Digital Pressure Sensors

GP-M series

Select Language

Model

GP-M001

GP-M010

GP-M025

GP-M100

GP-M250

GP-M400

Rated pressure

-14.50 to +14.50 PSI
(-100 to +100 kPa)

-14.5 to +145.0 PSI
(-0.1 to +1 MPa)

-14.5 to +362.6 PSI
(-0.1 to +2.5 MPa)

0 to +1450 PSI
(0 to +10 MPa)

0 to +3626 PSI
(0 to +25 MPa)

0 to+5802 PSI
(0 to+40 MPa)

Possible display range

-17.40 to +17.40 PSI
(-120.0 to +120.0 kPa)

-30.5 to +161.0 PSI
(-0.210 to +1.110 MPa)

-52.2 to +400.3 PSI
(-0.360 to +2.760 MPa)

-145 to +1595 PSI
(-1.00 to +11.00 MPa)

-363 to +3989 PSI
(-2.50 to +27.50 MPa)

-580 to+6382 PSI
(-4.00 to+44.00 MPa)

Zero-cut pressure value

±0.5% of F.S.

Allowable pressure

58 PSI (400 kPa)

580 PSI (4 MPa)

1450 PSI (10 MPa)

4351 PSI (30 MPa)

7252 PSI (50 MPa)

Burst pressure

217.5 PSI (1500 kPa)

2175 PSI (15 MPa)

5075 PSI (35 MPa)

14504 PSI (100 MPa)

Display resolution

kPa

0.1

1

None

MPa

None

0.001

0.01

PSI

0.01

0.1

1

bar

0.001

0.01

0.1

kgf/cm2

Fluid type

Gas or liquid that will not corrode the liquid contact part

Liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C 50°F

Connection port

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Medium temperature

-20 to +100°C -4°F to +212°F (no freezing/condensation)*3

Power voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis

During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)

Response

Control output

Selectable from 3 to 5000 ms

Analog output

As above + 2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmental
resistance

Ambient temperature

-20 to +80°C -4°F to +176°F (no freezing/condensation)

Relative humidity

35 to 85% RH (no condensation)

Vibration

IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)

Shock

IEC60068-2-27 50 G (11 ms, 3 times for each of X, Y and Z axis)

Enclosure rating

IP67

Material
properties

Wetted part

Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU

Applicable cable

M12 connector 4 pin

Weight

App. 150 g

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.
*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω