Digital Amplifier Functions

User-friendly Menu Structure and Easy-to-read Digital Display.

The FT-50AW(P) and FT-55AW(P) come with functions that can be used on-site, eliminating complexity and difficulty.

Complex Setting Calculations are Now Automatic

In the past, the correct temperature was displayed only when the emissivity that matched the material of the detection object was set correctly. For the FT Series, the user only has to enter the current temperature of the detection object. This is because the FT Series automatically calculates the emissivity from the entered current temperature. The user doesn't have to worry about complex emissivity calculations.

1. Enter the surface temperature directly.

Enter the surface

2. Pressing the“SET”button calculates and sets the optimum emissivity automatically.

Pressing the“SET”button calculates

What is the emissivity?

If two different materials have the same temperature, the quantity of far-infrared rays being emitted by each differs. This results in different emissivity values that are used to calculate temperature. Emissivity is based on a scale from 0 to 1 of the quantity of far-infrared rays being emitted from that material.

Example

Water: 0.92 to 0.96
Plastic: 0.85 to 0.95
Stainless steel: 0.45
Ceramic: 0.90 to 0.94

Other Functions That Expand the Scope of Applications

Analog monitor outputs*

The FT-50AW (P) and FT-55AW (P) provide analog monitor outputs (4 mA to 20 mA) corresponding to the displayed values.
Setting the upper and lower limit values provides simple scaling.

Initial status

Initial status

When the lower limit value is 392°F (200°C)
and the upper limit value is 752°F (400°C)

When the lower limit and the upper limit

2 outputs x 4 banks

The FT-50AW (P) and FT-55AW (P) can each store two upper-limit outputs and two lower-limit outputs. They can also be configured for up to 4 emissivities. This eliminates the need to reset emissivities for each product changeover.

Display Hold function

In the past, (amplifiers before the FT-50AW (P) and FT-55AW (P)), it was difficult to confirm the surface temperature of workpieces moving at high speed. The Display Hold function enables the user to confirm the surface temperature of moving workpieces at their own speed since it can store and display the instantaneous maximum temperature.

Timing function*

The Timing function only displays the upper and lower temperatures when the timing input is on. This prevents unnecessary temperature readings like that of the conveyor or background oven regardless of where they fall with respect to the upper and lower temperature settings.

IR mode

The IR mode displays the quantity of far-infrared rays received by the thermopile so that it acts like an intensity sensor. Because of
this, the FT-50AW (P) and FT-55AW (P) could be used just like a photoeye to detect presence or absense of hot materials.

Power Saving function

The Power Saving function provides a simplified display when the sensor is left alone for a fixed time.

* If the Analog Monitor Output function or the Timing function is used, up to two banks can be used.
If both functions are used, only one bank can be used.