Digital Infrared Temperature SensorFT series

FT-H30

Sensor Head

SPECIFICATIONS

Select Language

Model

FT-H30

Type

Mid to low temperature Long-range

Rated temperature range

0 to 500°C 32 to 932°F*1

Displayable temperature range

-50 to +520°C -58 to +968°F

Detecting distance

Unlimited *2

Measuring distance /
View diameter (example)

200/ø15 mm 7.87"/ø0.59"
400/ø18 mm 15.75"/ø0.71"
600/ø33 mm 23.62"/ø1.30"

Sight

2-point visible laser beam*3

Detecting element

Thermopile

Detecting wavelength

8 to 14 μm 0.31 to 0.55 Mil

Repeatability

±0.5°C 31.1 to 32.9°F

Emissivity (ε) correction

0.10 to 1.99 (0.01 step)

Environmental resistance

Operating temperature range

-10 to 55°C 14 to 131°F, No freezing

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions

Shock resistance

500 m/s2, 10 times in each direction of each axis (X, Y, Z), 60 times in total

Material

Main unit

Case: Reinforced glass plastic, Infrared collector lens: Germanium, Laser transmitter: Polyarylate
Lens tube*4: Aluminum, Cable: Vinyl chloride, Mounting bracket: SUS304, Mounting screw: Stainless steel

Mounting bracket

SUS304

Accessories

Mounting bracket

Weight

Approx 120 g

*1 Repeatability is guaranteed within the rated temperature range.
*2 Place at a distance so that object appears 1.5 times larger than the view diameter.
*3 Visible semiconductor laser beam wavelength 655 nm, Class 1 Laser Product [IEC60825-1, FDA (CDRH) Part1040.10]. The laser classification for FDA (CDRH) is implemented based on IEC 60825-1
in accordance with the requirements of Laser Notice No.50.
*4 No lens tube on models FT-H10, FT-H20, and FT-H30.