Safety Laser ScannerSZ-V series

SZ-V32

Multi bank type

SPECIFICATIONS

Select Language

Model

SZ-V32

Type

Multi-bank Model

Detection capability

Minimum detectable object size

Diameter 20, 30, 40, 50, 70, 150 mm 0.79", 1.18", 1.58" ,1.97", 2.76" ,5.91" (selectable)
Reflectance 1.8 % min., Speed 1.6 m/s 5.2 ft/s max. *1

Detectable angle

190°(-5° to 185°)

Response time (ON to OFF)

Standard Mode

Scan Cycle A

160 ms (2 scans) to 1280 ms (16 scans) *2*3

Scan Cycle B

168 ms (2 scans) to 1344 ms (16 scans) *2*3

Scan Cycle C

176 ms (2 scans) to 1408 ms (16 scans) *2*3

High Speed Mode

Scan Cycle A

80 ms (2 scans) to 640 ms (16 scans) *2*3

Scan Cycle B

84 ms (2 scans) to 672 ms (16 scans) *2*3

Scan Cycle C

88 ms (2 scans) to 704 ms (16 scans) *2*3

Response time (OFF to ON)

Response time (ON to OFF) + 150 ms

Protection zone

Minimum detectable object size: 70 / 150 mm 2.76"/ 5.91"

8.4 m 27.6' (Standard Mode) 5.7 m 18.7' (High Speed Mode)

Minimum detectable object size: 50 mm 1.97"

5.6 m 18.4' (Standard Mode) 3.8 m 12.5' (High Speed Mode)

Minimum detectable object size: 40 mm 1.58"

4.3 m 14.1' (Standard Mode) 2.9 m 9.5' (High Speed Mode)

Minimum detectable object size: 30 mm 1.18"

2.9 m 9.5' (Standard Mode) 2.0 m 6.6' (High Speed Mode)

Minimum detectable object size: 20 mm 0.79"

1.6 m 5.2' (Standard Mode) 1.1 m 3.6' (High Speed Mode)

Warning zone

Minimum detectable object size: 70 / 150 mm 2.76"/ 5.91"

26 m 85.3' (Standard Mode) 23 m 75.5' (High Speed Mode)*4

Minimum detectable object size: 50 mm 1.97"

25 m 82.0' (Standard Mode) 21 m 68.9' (High Speed Mode)*4

Minimum detectable object size: 40 mm 1.58"

24 m 78.7' (Standard Mode) 20 m 65.6' (High Speed Mode)*4

Minimum detectable object size: 30 mm 1.18"

23 m 75.5' (Standard Mode) 18 m 59.1' (High Speed Mode)*4

Minimum detectable object size: 20 mm 0.79"

21 m 68.9' (Standard Mode) 15 m 49.2' (High Speed Mode)*4

Additional safety distance

100 mm 3.94" *5

Maximum measurement distance

60 m 196.9' *6

Maximum number of banks

Max 32 banks

Multiple scanner heads

Max 3

Monitor camera

-*7

Display

QVGA 2.2 inch color LCD

Light source

Type, wavelength

Infrared laser diode, 905 nm

Laser class

IEC

Class1 IEC / EN60825-1

FDA

Class1 FDA 21CFR 1040.10、1040.11(Laser Notice No. 50)*8

JIS

Class1 JIS C6802

Control Output (OSSD)

Output

Transistor outputs (NPN or PNP is selected by the dedicated PC software)

Number of outputs

2 outputs

Max. load current

500 mA *9

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

OFF-state voltage

Max. 2.0 V (with a cable length of 5 m 16.4')

Leakage current

Max. 1 mA *10

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω

Input

PNP

ON-voltage: 10 to 30 V
OFF-voltage: Open or 0 to 3 V
Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM)

NPN

ON-voltage: 0 to 3 V
OFF-voltage: Open or
10 V to Power voltage
Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM)

Non safety related output (AUX output)

Output type

Transistor outputs (NPN or PNP is selected by the dedicated PC software)

Number of outputs

4 outputs

Max. load current

Max. 50 mA

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

Muting lamp

-

Interface

USB

USB 2.0

Ethernet

Standard

-

Transmission rate

Cable

Connector

Network function

Cable length

Power and I/O cable

30 m 98.4' or less *11

between scanner head and I/O unit

20 m 65.6' or less *12

Ethernet cable

-

Approved standards

EMC

EMS

IEC61496-1、EN61496-1、UL61496-1(Type 3 ESPE)

EMI

EN55011 ClassA、FCC Part15B ClassA、ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE),
IEC61496-3, EN61496-3 (Type3 AOPDDR),
IEC61508, EN61508, IEC62061, EN62061 (SIL2/SILCL2),
EN ISO13849-1:2015 (PLd, Category3), UL508, UL1998,
CSA C22.2 No. 14, CSA C22.2 No. 0.8

Rating

Power voltage

24 VDC ±10 % (Ripple P-P 10 % or less): When using a converter power supply
24 VDC +20 % / -30 %: When using a battery

Power consumption

11.8 W(without load) 55.0 W(with loads) *13

Environmental resistance

Enclosure protection

IP65 (IEC60529)

Operating ambient temperature

-10 to +50 °C 14 to 122°F (No freezing)

Storage ambient temperature

-25 to +60 °C -13 to 140°F (No freezing)

Operating relative humidity

35 % to 85 % RH (No condensation)

Storage relative humidity

35 % to 95 % RH

Surrounding light

Incandescent lamp: 1500 lux or less *14

Vibration

10 to 55 Hz, 0.7 mm 0.03" compound amplitude,
20 sweeps each in X, Y, and Z directions

Shock

100 m/s2 (Approx. 10 G)
16 ms pulse, in X, Y, Z directions 1,000 times each axis

Material

Scanner head

Main unit case

Magnesium

Window

Polycarbonate, PEI

Indicator part

-*7

Display unit

case

Magnesium, PPS, Polycarbonate

System memory

Aluminum, PPE

Weight

Approx. 2100 g

*1 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting.
*2 When using the SZ-V with series connected scanner heads, the first scanner head is scan cycle A, the second scanner head is scan cycle B, and the third scanner head is scan cycle C.
*3 The response time, protection zone, and warning zone is determined by the operation mode.
*4 20 % or more reflectance is necessary for the minimum detectable object in the warning zone.
*5 If there is a highly reflective background within 1.5 m 4.9' from the boundary of the protection zone, 200 mm 7.87" must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance.
*6 Even when using the network data output, the maximum measured output distance is 60 m 196.9'.
*7 Only applicable for a type with a camera.
*8 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No. 50.
*9 For the SZ-V04 type and the SZ-V32 type, the load current calculation of the OSSD output and AUX output is 1.5 A or less when using one scanner head, 1.0 A or less when using two scanner heads, and 0.5 A or less when using three scanner heads. For the SZ-V32N type, the load current calculation of the OSSD output and AUX output is 1.2 A or less when using one scanner head, 0.8 A or less when using two scanner heads, and 0.3 A or less when using three scanner heads.
*10 Includes when the power is OFF.
*11 10 m 32.8' or less when supplying power from a battery.
*12 When supplying power from a battery, the length of each connection cable should be 10 m 32.8' or less when using two scanner heads, and 5 m 16.4' or less when using three scanner heads.
*13 When using the SZ-V with series connected scanner heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation.
*14 An ambient light source should not be located within ±5 ° of the detection plane.

Latest / Most Downloaded

    • General Catalog Request
    • Trade Shows and Exhibitions
    • eNews Subscribe

    Safety