Safety Light Curtain

SL-C series

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Recommended Replaceable Products: Safety Light Curtain - GL-R series

Main Unit, General-purpose Type, 40 Optical Axes SL-C40H

SL-C40H - Main Unit, General-purpose Type, 40 Optical Axes

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • UL Listing(c/us)

Specifications

Model

SL-C40H

Effective aperture angle

Max. ±2.5° (when operating distance is at least 3 m 9.8')

Response time

15 ms *1

Light source

Infrared LED (850 nm)

Detection capability

ø25 mm (when the blanking function is not used)

Operation mode

Turned on when light is being applied to all optical axes (excluding when the blanking function is used)

No. of beam axes

40

Detection zone

780 mm 30.71"

Protection area

825 mm32.48"

DetectingdistanceTransmitter lens: Norbornene plasticReceiver lens cover: Polyarylate

0.3 to 9 m

Operating distance/Beam width

0.3 to 9 m 0.98' to 29.5'

Beam axis interval

20 mm 0.79"

Lens diameter

5 mm0.20" dia.

OSSD output

Output type

2 outputs each for PNP and NPN, Can be switched using the connection connector cable

Max. load current

300 mA *2

OFF-state voltage

2.5 V (with a cable length of 7 m 23.0')

Leakage current

100 µA maximum*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

2.5 Ω maximum*4

Approved standards

EMC

EMS

UL61496-1

EMI

FCC Part15 Class A

Safety

UL61496-1 (type 4 ESPE), UL61496-2 (type 4 AOPD),UL508

Current consumption

Transmitter

81 mA

Receiver

86 mA

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Storage temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage relative humidity

35 to 95 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate

Weight

Transmitter

Approx 525 g

Receiver

Approx 575 g

*1 OFF→ON return time is 125 ms.
*2 Note the derating illustrated in the graph to the right when using PNP output.
*3 This includes situations in which the SL-C Series is off and in which the power supply line is disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 Ω or less to ensure that the SL-C Series operate correctly. If using the NPN output

Data Sheet (PDF) Other Models