Safety Light Curtain

SL-V series

Select Language

Model

SL-V23F

SL-V31F

SL-V39F

SL-V47F

SL-V55F

SL-V63F

SL-V71F

Detection capability

ø0.55" ø14 mm

Beam axis spacing/Lens diameter

10 mm/ø4 mm 0.39"/ø0.16"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 7.0 m 0.30' to 22.97'

Response time (ms)

ON→OFF

9.1*1

10.2*1

11.3*1

12.4*1

13.5*1

14.6*1

15.7*1

OFF→ON

49.1*1

50.2*1

51.3*1

52.4*1

53.5*1

54.6*1

55.7*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN61000-6-2, EN55011 Class A, FCC Part15B Class A

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

83*6

93*6

103*6

112*6

121*6

129*6

136*6

Receiver

78*6

80*6

82*6

85*6

87*6

89*6

92*6

When the center indicator is OFF

Transmitter

80*6

90*6

99*6

107*6

115*6

122*6

129*6

Receiver

74*6

75*6

77*6

78*6

80*6

82*6

83*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

200 g

270 g

330 g

390 g

450 g

510 g

570 g

Receiver

205 g

275 g

345 g

405 g

465 g

525 g

585 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V79F

SL-V87F

SL-V95F

SL-V103F

SL-V111F

SL-V119F

SL-V127F

Detection capability

ø0.55" ø14 mm

Beam axis spacing/Lens diameter

10 mm/ø4 mm 0.39"/ø0.16"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 7.0 m 0.30' to 22.97'

Response time (ms)

ON→OFF

16.8*1

17.9*1

19*1

20.1*1

21.2*1

22.3*1

23.4*1

OFF→ON

56.8*1

57.9*1

59*1

60.1*1

61.2*1

62.3*1

63.4*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

142*6

148*6

154*6

159*6

163*6

166*6

169*6

Receiver

94*6

97*6

99*6

101*6

104*6

106*6

109*6

When the center indicator is OFF

Transmitter

135*6

140*6

145*6

149*6

152*6

156*6

158*6

Receiver

85*6

87*6

88*6

90*6

92*6

93*6

95*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

620 g

670 g

720 g

760 g

810 g

850 g

890 g

Receiver

635 g

685 g

735 g

775 g

815 g

855 g

895 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V23FM

SL-V31FM

SL-V39FM

SL-V47FM

SL-V55FM

SL-V63FM

SL-V71FM

Detection capability

ø0.55" ø14 mm

Beam axis spacing/Lens diameter

10 mm/ø4 mm 0.39"/ø0.16"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 7.0 m 0.30' to 22.97'

Response time (ms)

ON→OFF

9.1*1

10.2*1

11.3*1

12.4*1

13.5*1

14.6*1

15.7*1

OFF→ON

49.1*1

50.2*1

51.3*1

52.4*1

53.5*1

54.6*1

55.7*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

83*6

93*6

103*6

112*6

121*6

129*6

136*6

Receiver

78*6

80*6

82*6

85*6

87*6

89*6

92*6

When the center indicator is OFF

Transmitter

80*6

90*6

99*6

107*6

115*6

122*6

129*6

Receiver

74*6

75*6

77*6

78*6

80*6

82*6

83*6

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

670 g

830 g

990 g

1150 g

1300 g

1460 g

1610 g

Receiver

680 g

840 g

1000 g

1160 g

1320 g

1470 g

1630 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V79FM

SL-V87FM

SL-V95FM

SL-V103FM

SL-V111FM

SL-V119FM

SL-V127FM

Detection capability

ø0.55" ø14 mm

Beam axis spacing/Lens diameter

10 mm/ø4 mm 0.39"/ø0.16"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 7.0 m 0.30' to 22.97'

Response time (ms)

ON→OFF

16.8*1

17.9*1

19*1

20.1*1

21.2*1

22.3*1

23.4*1

OFF→ON

56.8*1

57.9*1

59*1

60.1*1

61.2*1

62.3*1

63.4*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

142*6

148*6

154*6

159*6

163*6

166*6

169*6

Receiver

94*6

97*6

99*6

101*6

104*6

106*6

109*6

When the center indicator is OFF

Transmitter

135*6

140*6

145*6

149*6

152*6

156*6

158*6

Receiver

85*6

87*6

88*6

90*6

92*6

93*6

95*6

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1760 g

1900 g

2050 g

2190 g

2330 g

2470 g

2590 g

Receiver

1770 g

1910 g

2060 g

2200 g

2460 g

2600 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V08H

SL-V12H

SL-V16H

SL-V20H

SL-V24H

SL-V28H

SL-V32H

SL-V36H

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm / ø5 mm 0.79" / ø0.20"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 9.0 m 0.30' to 29.53' (detection height of 1260 mm 49.61" or l ess)
0.1 m to 7.0 m 0.30' to 22.97' (detection height of 1400 mm 55.12" or more)

Response time (ms)

ON→OFF

7*1

7.6*1

8.1*1

8.7*1

9.2*1

9.8*1

10.3*1

10.9*1

OFF→ON

47*1

47.6*1

48.1*1

48.7*1

49.2*1

49.8*1

50.3*1

50.9*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

56*6

63*6

69*6

75*6

81*6

87*6

93*6

98*6

Receiver

70*6

72*6

74*6

77*6

79*6

80*6

82*6

When the center indicator is OFF

Transmitter

52*6

58*6

64*6

70*6

76*6

81*6

86*6

91*6

Receiver

65*6

66*6

67*6

68*6

69*6

70*6

71*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

150 g

200 g

250 g

300 g

350 g

400 g

450 g

500 g

Receiver

155 g

205 g

265 g

315 g

365 g

415 g

465 g

515 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V40H

SL-V44H

SL-V48H

SL-V52H

SL-V56H

SL-V60H

SL-V64H

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm / ø5 mm 0.79" / ø0.20"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 9.0 m 0.30' to 29.53' (detection height of 1260 mm 49.61" or l ess)
0.1 m to 7.0 m 0.30' to 22.97' (detection height of 1400 mm 55.12" or more)

Response time (ms)

ON→OFF

11.4*1

12*1

12.5*1

13.1*1

13.6*1

14.2*1

14.7*1

OFF→ON

51.4*1

52*1

52.5*1

53.1*1

53.6*1

54.2*1

54.7*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

103*6

108*6

113*6

117*6

122*6

126*6

130*6

Receiver

84*6

85*6

87*6

88*6

90*6

91*6

93*6

When the center indicator is OFF

Transmitter

96*6

100*6

104*6

109*6

112*6

116*6

120*6

Receiver

72*6

73*6

74*6

75*6

76*6

77*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

550 g

600 g

650 g

700 g

750 g

800 g

860 g

Receiver

575 g

625 g

675 g

725 g

775 g

835 g

885 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V72H

SL-V80H

SL-V88H

SL-V96H

SL-V104H

SL-V112H

SL-V120H

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm / ø5 mm 0.79" / ø0.20"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 9.0 m 0.30' to 29.53' (detection height of 1260 mm 49.61" or l ess)
0.1 m to 7.0 m 0.30' to 22.97' (detection height of 1400 mm 55.12" or more)

Response time (ms)

ON→OFF

15.8*1

16.9*1

18*1

19.1*1

20.2*1

21.3*1

22.4*1

OFF→ON

55.8*1

56.9*1

58*1

59.1*1

60.2*1

61.3*1

62.4*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

137*6

144*6

149*6

154*6

159*6

162*6

165*6

Receiver

96*6

98*6

101*6

104*6

107*6

109*6

112*6

When the center indicator is OFF

Transmitter

126*6

132*6

136*6

140*6

143*6

146*6

147*6

Receiver

78*6

80*6

81*6

83*6

84*6

86*6

87*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

960 g

1060 g

1160 g

1260 g

1360 g

1460 g

1570 g

Receiver

985 g

1095 g

1195 g

1295 g

1405 g

1505 g

1615 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V12HM

SL-V16HM

SL-V20HM

SL-V24HM

SL-V28HM

SL-V32HM

SL-V36HM

SL-V40HM

SL-V44HM

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm / ø5 mm 0.79" / ø0.20"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 9.0 m 0.30' to 29.53' (detection height of 1260 mm 49.61" or l ess)
0.1 m to 7.0 m 0.30' to 22.97' (detection height of 1400 mm 55.12" or more)

Response time (ms)

ON→OFF

7.6*1

8.1*1

8.7*1

9.2*1

9.8*1

10.3*1

10.9*1

11.4*1

12*1

OFF→ON

47.6*1

48.1*1

48.7*1

49.2*1

49.8*1

50.3*1

50.9*1

51.4*1

52*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

63*6

69*6

75*6

81*6

87*6

93*6

98*6

103*6

108*6

Receiver

72*6

74*6

77*6

79*6

80*6

82*6

84*6

85*6

When the center indicator is OFF

Transmitter

58*6

64*6

70*6

76*6

81*6

86*6

91*6

96*6

100*6

Receiver

66*6

67*6

68*6

69*6

70*6

71*6

72*6

73*6

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

670 g

810 g

960 g

1110 g

1250 g

1400 g

1540 g

1690 g

1830 g

Receiver

680 g

830 g

970 g

1120 g

1270 g

1410 g

1560 g

1710 g

1850 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-V48HM

SL-V52HM

SL-V56HM

SL-V60HM

SL-V64HM

SL-V72HM

SL-V80HM

SL-V88HM

SL-V96HM

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm / ø5 mm 0.79" / ø0.20"

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 m to 9.0 m 0.30' to 29.53' (detection height of 1260 mm 49.61" or l ess)
0.1 m to 7.0 m 0.30' to 22.97' (detection height of 1400 mm 55.12" or more)

Response time (ms)

ON→OFF

12.5*1

13.1*1

13.6*1

14.2*1

14.7*1

15.8*1

16.9*1

18*1

19.1*1

OFF→ON

52.5*1

53.1*1

53.6*1

54.2*1

54.7*1

55.8*1

56.9*1

58*1

59.1*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 μA*3

Max. capacitive load

2.2 μF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMC

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

113*6

117*6

122*6

126*6

130*6

137*6

144*6

149*6

154*6

Receiver

87*6

88*6

90*6

91*6

93*6

96*6

98*6

101*6

104*6

When the center indicator is OFF

Transmitter

104*6

109*6

112*6

116*6

120*6

126*6

132*6

136*6

140*6

Receiver

74*6

75*6

76*6

77*6

78*6

80*6

81*6

83*6

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Overvoltage category

II

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Relative humidity

15 to 85 % RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1980 g

2130 g

2270 g

2420 g

2560 g

2850 g

3140 g

3440 g

3730 g

Receiver

2000 g

2150 g

2290 g

2440 g

2590 g

2880 g

3170 g

3470 g

3760 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the
response times of al l the individual SL-V units, but the response time (OFF to ON) is the same
as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and
SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6
ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55°C 113 to 131°F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cabl e) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable
length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55°C 113.0 to 131.0°F , use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by
10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the
receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of
both transmitter and receiver is fixed.)
• In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the
OFF state.
• In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON
state.

Model

SL-T11R

Combined light curtain

SL-V Series

Output

FSD1、2

230 VAC, 4 A 30 VDC, 2 A (Resistance load)/230 VAC, 2 A (COSø=0.3) (Inductive load)/30 VDC, 1 A (COSø=0.3) (Inductive load)*1

Life-span

Mechanical life: 10 million cycles or more/Electrical life: 0.1 million cycle or more*1

Response time (ms)

ON→OFF

+6 ms

OFF→ON

+15ms

Approved standards

EMC

EMS

UL61496-1, IEC61496-1, EN61496-1

EMC

FCC Part15B Class A, ICES-003 Class A, EN55011 Class A

Safety

UL61496-1, IEC61496-1, EN61496-1 (Type 4 ESPE), ISO 13849-1: 2015 (Cat 4 PLe),UL508, EN50178

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption.

100 mA or less (at 24 VDC, SL-T11R alone)

Environmental resistance

Enclosure rating

IP20 (IEC60529)
Set inside control panel with IP54 or more

Environmental
resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

15 to 85 % RH (No condensation)

Environmental resistance

Pollution degree

2

Overvoltage category

III

Ambient temperature for storage

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Polycarbonate

Weight

Approx. 330 g

*1 For the specifications for the outputs other than FSD and for each input, refer to the SL-V Instruction Manual.

Model

SL-U2

System

Switching type

Input power supply voltage

100 to 240 VAC ±10% (50/60 Hz)

Ripple/noise

240 mV p-p or less

Output capacity

1.8A

Supply voltage interruption

10 ms max.

Approved standards

EMC

EN61000-6-2, EN55011 Class A, FCC Part15 Class A

Safety

EN60950-1, EN50178, UL60950-1, UL508

Rating

Power voltage

24 VDC ±10 %, Class 2

Environmental resistance

Withstand voltage

1,500 VAC, 1 min. (between all external terminals and case)

Insulation resistance

At least 50 MΩ
(500 VDC mega, between all external terminals and case)

Environmental
resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Environmental resistance

Pollution degree

2

Overvoltage category

II

Vibration

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Weight

Approx. 240 g

  • General Catalog Request
  • Trade Shows and Exhibitions
  • eNews Subscribe

Safety