Digital Fiber Optic SensorsFS-N series (FS-neo)

FS-N12N

Fiber Amplifier, Cable Type, Expansion Unit, NPN

SPECIFICATIONS

Select Language

Model

FS-N12N

Type

Standard 1 output
Cable

Output

NPN

Main unit/expansion unit

Expansion unit

Control output

1
NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

Monitor output (1-5 V)

-

External input

Response time

50 μs (HIGH SPEED)/250 μs (FINE)/500 μs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)

Multiple connections to Expansion units

Up to 16 units can be connected total (two output type is treated as two units)

Light source LED

Red, 4-element LED

APC

ON/OFF switchable (Factory setting: OFF)

Number of interference prevention units

0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)

Rating

Power voltage

12 - 24 V DC ±10% ripple (P-P) 10% or less

Current Consumption

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1
Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1
Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

Environmental
resistance

Operating ambient luminance

Incandescent lamp: 20000 lux or less; Sunlight: 30000 lux or less

Operating ambient temperature

-20 to +55 °C -4 to +131 °F (no freezing)*2

Operating ambient humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 55 Hz Compound amplitude 1.5 mm 0.06", 2 hours for each of X,Y,Z axis

Shock resistance

500 m/s2 3 times for each of X,Y,Z axis

Case material

Both main unit and expansion unit housing material: Polycarbonate

Weight

Approx. 45 g

*1 Increases 100 mW (4.0 mA) for High Speed mode
*2 One or two more units connected: -20 to +55°C (-4 to +131°F); 3 to 10 more units connected: -20 to +50°C (-4 to +122°F); 11 to 16 more units connected: -20 to +45°C (-4 to +113°F).
When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.