Digital Fiber Optic SensorsFS-N series (FS-neo)

FU-70U

Transmissive Fiber Unit

SPECIFICATIONS

Select Language

Model

FU-70U

Optical axis diameter
(Standard target to be detected)

ø2.3 mm0.091"

Fibre unit length

1 m39.37" free-cut

Ambient temperature

-40 to +50°C -40 to 122°F (no freezing)

Operating ambient humidity

35 to 85% RH (No condensation)

Minimum bend radius

R2 mm0.079"

Detection distance

MEGA/FINE

MEGA

1800 mm70.866"

FINE

850 mm33.465"

Other power modes

ULTRA

1800 mm70.866"

SUPER

TURBO

1200 mm47.244"

HSP

370 mm14.567"

Minimum detectable object

Opaque material with a diameter of 0.1 mm0.004"*1

Tightening torque

0.8 Nm

Material

Core fiber : acrylic, fiber sheath : nylon, case : nickel-plated brass, lens : glass (BK7)

Accessories

Fiber cutter, FU adapter, mounting screws

Weight

Approx 5 g

*1 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

  • General Catalog Request
  • Trade Shows and Exhibitions
  • eNews Subscribe

Sensors