FS-V20 seriesDigital Fiber Optic Sensors

FS-V21RP

Fiber Amplifier, Cable Type, Main Unit, PNP

SPECIFICATIONS

Select Language

Model

FS-V21RP

Type

Main unit:PNP output

Light source

Red, 4-element LED

Response time

250 μs (FINE)/500 μs (TURBO)/1 ms (SUPER TURBO)/4 ms (ULTRA TURBO)/500 μs (HIGH RESOLUTION)/50 μs (HIGH SPEED)

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Detection mode

Light intensity/rising edge/falling edge

Display shift function

Max. ±1999 (variable)

Timer
function

Mode

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, selectable

Accuracy

±10% of the Preset Value

Variable range

1 to 30 ms (in 1 ms increments), 30 to 50 ms (in 2 ms increments), 50 to 200 ms (in 10 ms increments), 200 to 500 ms (in 50 ms increments)

Control
output

PNP open-collector 100 mA max. (30 VDC max.) *4,
Residual voltage: 1 V max.

Monitor output *1

*1

No. of expansion units *2

Up to 16 expansion units can be connected (a total of 17 units).*2

Mutual interference
suppression

HIGH SPEED/ HIGH RESOLUTION: 0, FINE : 4, TURBO/SUPER/ULTRA: 8

Rating

Power voltage

12 to 24 VDC ±10%, ripple: 10% max., Class 2

Power consumption

Normal

S-APC OFF: 650 mW max.(27 mA max. at 24 VDC), S-APC ON: 720 mW max.(30 mA max. at 24 VDC)

Power consumption*3

Normal(S-APC ON)

720 mW (30 mA or less)*3

Normal(S-APC OFF)

650 mW (27 mA or less)*3

Current
consumption

ECO half

S-APC OFF: 530 mW max.(22 mA max. at 24 VDC), S-APC ON: 660 mW max.(25 mA max. at 24 VDC)

Rating

Power consumption*3

S-APC ON(Eco-Half)

660 mW (25 mA or less)*3

Eco-Half(S-APC OFF)

530 mW (22 mA or less)*3

Current
consumption

ECO all

S-APC OFF: 480 mW max.(20 mA max. at 24 VDC), S-APC ON: 550 mW max.(23 mA max. at 24 VDC)

Rating

Power consumption*3

Eco-All(S-APC ON)

550 mW (23 mA or less)*3

Eco-All(S-APC OFF)

480 mW (20 mA or less)*3

Environmentalresistance

Operating Ambient illumination

Incandescent lamp: 20000 lux max., Sunlight: 30000 lux max.

Operating ambient temperature

-10 to +55°C (14 to 131°F), No condensation

Operating ambient humidity

35 to 85%RH(no condensation)

Vibration resistance

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours each in the X, Y and Z axis

Shock resistance

500 m/s2 in X, Y, and Z directions, 3 times respectively

Case material

Polycarbonate

Size

30 mm (H) x 9 mm (W) x 70 mm (D) 1.18" (H) x 0.35" (W) x 2.76" (D)

Weight(including 2-m 6.6' cable)

Approx 80 g

*1 Use the FS-V21RM in the FINE or TURBO mode when outputting signals with a monitor.
*2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
1 or 2 Units: -10 to 55°C (14 to 131°F), 3 to 10 Units: -10 to 50°C (14 to 122°F), 11 to 16 Units: -10 to 45°C (14 to 113°F)
*3 When HIGH RESOLUTION has been selected, S-APC ON is fixed. When HIGH SPEED has been selected, S-APC ON is fixed for the R type and for anything other than the R type, S-APC OFF is fixed. For others, the factory setting is S-APC OFF. The value inside the parentheses is the current consumption when using a 24 VAC power supply voltage
*4 20 mA at maximum for the expansion unit.