Digital Fiber Optic SensorsFS-V20 series

FU-V7FN

Transmissive Fiber Unit

SPECIFICATIONS

Select Language

Model

FU-V7FN

Type

Atmosphere-side fiber unit (thrubeam model heat resistant to 70°C 158°F)

Detecting method

Thrubeam

Fibre unit diameter

ø2.2

Minimum bend radius

R25 mm0.984" or more

Detection distance

MEGA/FINE

MEGA

1,300 mm51.181"*1

FINE

270 mm10.63"*1

Other power modes

ULTRA

720 mm28.346"*1

SUPER

500 mm19.685"*1

TURBO

360 mm14.173"*1

HSP

135 mm5.315"*1

Minimum detectable object

Opaque material with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 30 g

*1 Used as a thrubeam model when the FU-V84, FU-V84L, FU-VJ1, or FU-V7FN is connected.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.