Manual-Calibration Fiberoptic SensorFS-V/T/M series (FS01)

FU-70U

Transmissive Fiber Unit

SPECIFICATIONS

Select Language

Model

FU-70U

Optical axis diameter
(Standard target to be detected)

ø2.3 mm0.091"

Fibre unit length

1 m39.37" free-cut

Minimum bend radius

R2 mm0.079"

Detection distance

MEGA/FINE

MEGA

1800 mm70.866"

FINE

850 mm33.465"

Other power modes

ULTRA

1800 mm70.866"

SUPER

TURBO

1200 mm47.244"

HSP

370 mm14.567"

Minimum detectable object

Opaque material with a diameter of 0.1 mm0.004"*1

Tightening torque

0.8 Nm

Environmental resistance

Ambient temperature

-40 to +50 °C -40 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Core fiber : acrylic, fiber sheath : nylon, case : nickel-plated brass, lens : glass (BK7)

Accessories

Fiber cutter, FU adapter, mounting screws

Weight

Approx. 5 g

*1 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.