FS-V/T/M series (FS01)

Manual-Calibration Fiberoptic Sensor

Select Language

Model

NPN

FS-V1

PNP

FS-V1P

Type

Main unit

Light source

Red LED

Response time

250 μs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Display indicator (Two): Red LED
Received light display: LCD
(Two color display: Red and green)
Calibration indicator: Orange LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Control output

NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max. The FS-V1P is equipped with two outputs.

Protection circuit

Reversed polarity protection, over-current protection, surge absorber

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units)*1

Mutual interference suppression

4

Rating

Power voltage

12 to 24 VDC (±10%), ripple (p-p): 10% max.,Class 2*2

Current consumption.

50 mA or less

Environmental resistance

Operating ambientluminance

Incandescent lamp: 10,000 lux max.,
Sunlight: 20,000 lux max.

Operating temperature range

-10 to 55°C (14 to 131°F), No condensation*3

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours each in the X, Y and Z axis

Shock resistance

500 m/s2 in X, Y, and Z directions, 3 times respectively

Case material

Polycarbonate

Weight

Approx. 80 g

*1 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
*2 Neither the FS-V12 nor the FS-V10 can be used as a standalone unit.
*3 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended

Model

NPN

FS-T1

FS-T2

FS―M1

FS―M2

PNP

FS-T1P

FS-T2P

FS―M1P

FS―M2P

Type

Main unit

1-line expansion unit

Main unit

1-line expansion unit

Light source

Red LED

Sensitivity adjustment/Mode selection

Button

8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

Response time

250 μs

250 μs (FINE)/500 μs (TURBO)

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED

Output: Red LED
Stable operation: Green LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Input

Non-voltage input (contact, solid state)

Control output

NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

Stability output

NPN open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max. *1

Protection circuit

Reversed polarity protection, over-current protection, surge absorber

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units)*2

Mutual interference suppression

4

FINE : 4, TURBO/SUPER: 8

Rating

Power voltage

12 to 24 VDC ±10%, ripple (P-P): 10% or less

12 to 24 VDC (±10%), ripple (p-p): 10% max.*4

12 to 24 VDC ±10%, ripple (P-P): 10% or less

12 to 24 VDC (±10%), ripple (p-p): 10% max.*4

Current consumption.

35 mA or less

Environmental resistance

Operating ambientluminance

Incandescent lamp: 10,000 lux max.,
Sunlight: 20,000 lux max.

Operating temperature range

-10 to 55°C (14 to 131°F), No condensation*3

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours each in the X, Y and Z axis

Shock resistance

500 m/s2 in X, Y, and Z directions, 3 times respectively

Case material

Polycarbonate

Weight

Approx 75 g

Approx 40 g

Approx 75 g

Approx 40 g

*1 Only the FS-T1 and FS-M1 can provide stability outputs.
*2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
*3 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended
*4 Power to the FS-T2/M2 is supplied through the FS-T1/M1/V1/V11/, PS-T1, LV-21A/11A.

Model

FS-T1G

Light source

Green LED

Response time

250 μs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Orange LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

External calibration input
signal

Non-voltage input (contact, solid state)

Input

Control output

NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

Stability output

NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max

Protection circuit

Reversed polarity protection, over-current protection, surge absorber

Rating

Power voltage

12 to 24 VDC ±10%, ripple (P-P): 10% or less

Current consumption.

35 mA or less

Environmental resistance

Operating ambientluminance

Incandescent lamp: 10,000 lux max.,
Sunlight: 20,000 lux max.

Operating temperature range

-10 to 55°C (14 to 131°F), No condensation*1

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours each in the X, Y and Z axis

Shock resistance

500 m/s2 in X, Y, and Z directions, 3 times respectively

Case material

Polycarbonate

Weight

Approx 75 g

*1 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended

Model

FS-M1H

Light source

Red LED

Sensitivity adjustment/Mode selection

8-turn trimmer (with indicator),
FINE/TURBO (switch-selectable)

Response time

20 μs (FINE)/ 50 μs (TURBO)

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Output: Red LED
Stable operation: Green LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Control output

NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

Stability output

NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max.

Protection circuit

Reversed polarity protection, over-current protection, surge absorber

Rating

Power voltage

12 to 24 VDC ±10%, ripple (P-P): 10% or less

Current consumption.

35 mA or less

Environmental resistance

Operating ambientluminance

Incandescent lamp: 10,000 lux max.,
Sunlight: 20,000 lux max.

Operating temperature range

-10 to 55°C (14 to 131°F), No condensation*1

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours each in the X, Y and Z axis

Shock resistance

500 m/s2 in X, Y, and Z directions, 3 times respectively

Case material

Polycarbonate

Weight

Approx 75 g

*1 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended

For visitors who viewed this page

    Latest / Most Downloaded

      • SensorCentral.com
      • Get FREE! General Catalog
      • Trade Shows and Exhibitions
      • eNews Subscribe

      Sensors