Fiber UnitFU series

FU-67TG

Reflective Fiber Unit

SPECIFICATIONS

Select Language

Model

FU-67TG

Type

Beam emitting direction

Detection arrangement

Parallel

Detecting method

Diffuse Reflective

Size

M6

Shape

Threaded

No. of beam axes

Optical axis width

Optical axis height

Fibre unit length

1 m39.37" cannot be cut

Fibre unit diameter

Optical axis diameter
(Standard target to be detected)

Minimum bend radius

R10 mm0.394" , stainless

Mounting transparent tube diameter

Aperture angle

Standard detection object

Detection distance

Detection distance

SUPER TURBO

MEGA/FINE

MEGA

710 mm27.953"*1

FINE

210 mm8.268"*1

Other power modes

ULTRA

550 mm21.654"*1

SUPER

470 mm18.504"*1

TURBO

310 mm12.205"*1

HSP

90 mm3.543"*1

When using the FS-V30 Series

When APC is on

MEGA

400 mm15.748"*1

ULTRA

320 mm12.598"*1

SUPER

160 mm6.299"*1

TURBO

120 mm4.724"*1

FINE

60 mm2.362"*1

HIGH SPEED

33 mm1.299"*1

When APC is off

MEGA

500 mm19.685"*1

ULTRA

400 mm15.748"*1

SUPER

200 mm7.874"*1

TURBO

150 mm5.906"*1

FINE

75 mm2.953"*1

HIGH SPEED

45 mm1.772"*1

Minimum detectable object

Gold wire with a diameter of 0.005 mm0.0002" *2

Focal distance

Hysteresis (of detecting distance)

Heat resistant temperature

*3

Spot

Slit (sold separately)

Repetition accuracy

Leak amount

Tightening torque

Overview

Enclosure rating

Ambient temperature

-40 to +50°C -40 to 122°F

Operating ambient humidity

Pressure resistance

Material

Accessories

Weight

Approx 32 g

*1 The detecting distance is a value for white mat paper (the standard detection object) detections.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.
*3 Use in a dry state. Also, when using the heat resistant type, make a selection with ample room for the ambient temperature.

Fiber Unit Finder

  • Fiber Unit Finder

Latest / Most Downloaded

    • General Catalog Request
    • Trade Shows and Exhibitions
    • eNews Subscribe

    Sensors