Network Communication UnitNU series

NU-PD1

PROFIBUS DP compatible Network Unit

NU-PD1 - PROFIBUS DP compatible Network Unit

Downloads

Catalogs

View Details
  • CE Marking
  • UL Listing(c/us)

SPECIFICATIONS

Select Language

Model

NU-PD1

Sensor connection

Connectable sensors

Sensors with N-bus support *1

Number of connectable units

16 units max. *2

Power supply

Power is supplied from the NU-PD1 via wiring-saving connector.

Allowable passing current

Overall 1200 mA or less *3

PROFIBUS
DP
specifications

Device type

DP-V1 Slave (D-sub9 pin, Number of the ports: 1)

Communication speed

9.6 kbit/s to 12 Mbit/s

Cable length

9.6 / 19.2 / 45.45 / 93.75 kbit/s : 1200 m
187.5 kbit/s : 1000 m
500 kbit/s : 400 m
1.5 Mbit/s : 200 m
3 / 6 / 12 Mbit/s : 100 m

Rating

Power voltage

24 VDC ±10%; ripple (P-P) 10% or less, Class 2 *4

Power consumption

1300 mW or less (at 24 V, 52 mA max.) *5

Environmental resistance

Operating temperature range

-20 to +55°C -4 to 131°F (no freezing) *6

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

IEC60068-2-6 2G (10 to 500 Hz, 2 hours each in X, Y, Z direction)

Shock resistance

IEC60068-2-27 30G (11 ms, 3 times each in X, Y, Z direction)

Material

Main unit case and dust cover: Polycarbonate
PROFIBUS connector: Steel – Nickel plating
Power supply connector: Polyamide (plug), PBT (socket)

Weight

Approx. 70 g (including connectors)

*1 N-bus is the name of KEYENCE's wiring-saving system for sensors.
*2 Varies with the sensors connected.
*3 Indicates the current that can be supplied to the NU-PD1 and to the sensors linked to the NU-PD1.
*4 Be sure to be used within the supply-voltage range of the sensor connecting to the NU-PD1.
*5 Exclusive of the current supplied to the sensors connected.
*6 1 to 2 units connected: -10 to +55°C 14 to 131°F, 3 to 10 units connected: -10 to +50°C 14 to 122°F,
11 to 16 units connected: -10 to +45°C 14 to 113°F
When a two-output type of sensor is connected, the sensor is counted as two units.