Self-Contained Full-Spectrum SensorLR-W series


Fiber type Cable type


Select Language




Fiber Type
2 m 6.56' cable type

Detecting distance

Detecting Distance and Min. Spot Diameter Based on Attached Fiber Head

Min. spot diameter

Response time

250 µs, 1 ms, 10 ms, 100 ms, 500 ms Selectable*1*2

Light source

White LED

Mutual interference reduction function

Up to 2 units when alternate frequencies set


OFF/ON delay/OFF delay/One-shot

Power supply

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

50 mA or less (without load) at 24 VDC;
90 mA or less (without load) at 12 VDC*3


Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, remaining voltage: 2 V or less
N.O./N.C. selectable

External input

Tuning /Transmission OFF selectable
Short circuit current: 1 mA or less for NPN/2 mA or less for PNP
For the applied voltage, see the wiring diagrams in the instruction manual.
For the input times, see the time charts in the instruction manual.

Protection circuit

Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Environmental resistance

Enclosure rating


Ambient light

Incandescent lamp: 10000 lux or less, Sunlight: 20000 lux or less

Ambient temperature

-20 to +45°C -4 to 113ºF (no freezing)

Ambient humidity

35 to 85%RH (no condensation)

Shock resistance

1000 m/s2 in X, Y, Z axis directions respectively 6 times

Vibration resistance

10 to 55 Hz Double amplitude 1.5 mm 0.06" in the X, Y, Z axis directions respectively, 2 hours


Case: Zinc die cast (Nickel chrome plating),
Indicator cover: PPSU, Buttons: PES,
Display: PMMA (scratch-resistant coating),
Cable bushing: PBT, Cable: PVC,
Fiber locking mount: PBT, NBR, Silicone rubber, SUS304, SUSXM7
Adapter: PBT


Approx. 150 g (including cable)

*1 When alternate frequencies are set, the response time increases by approximately 20%.
*2 When using the IO-Link communication, if the response time is set in 1ms or more, it becomes approximately 10% slower.
*3 160 mA or less (at 10 V, with load)
*4 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*5 When the following small-diameter fiber units (the diameter of the cable is ø1.3 ø0.05" or ø1.0 ø0.04") are used, the IP65 rating cannot be satisfied (FU-4F/66/91/93/43/63/63T etc.). When any small-diameter fiber units except for the above are used, IP65 is applied.
*6 When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit, the IP65 enclosure rating cannot be satisfied.

  • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors

Latest / Most Downloaded

    • General Catalog Request
    • Trade Shows and Exhibitions
    • eNews Subscribe