Self-contained CMOS Laser SensorLR-Z series

LR-ZB250AP

Rectangular Reflective Cable Type 250 mm

SPECIFICATIONS

Select Language

Model

LR-ZB250AP*1

Type

Distance setting 2 m cable

Appearance

Rectangular

Detectable distance

35 to 250 mm 1.38" to 9.84"
(215 to 0)*2

Standard detectable deviation

35 to 180 mm 1.38" to 7.09":, 9 mm 0.35", 180 to 250 mm 7.09" to 9.84":, 25 mm 0.98"

Display resolution

1 to 3 (1 to 3 mm 0.04" to 0.12")

Spot size

2.4 × 1.2 mm 0.09" x 0.05"
at 250 mm 9.84"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*3)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange), 1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 m 32.81' to 328.08'

Protection circuit

Protection against reverse power connection, output overcurrent,
output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less*4

Environmental
resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*5, Diversey*5

Ambient light

Incandescent lamp: 2000 lux or less
Sunlight: 4000 lux or less*6

Ambient temperature

-10 to +50°C 14 to 122°F (No freezing)

Storage temperature

-25 to +75℃ -13 to 167°F (No freezing)

Ambient humidity

35 to 85%RH (No condensation)

Shock resistance

1000 m/s2 in X, Y, Z axis directions respectively 6 times

Vibration resistance

10 to 55 Hz Double amplitude 1.5 mm 0.06" in the X, Y, Z
axis directions respectively, 2 hours

Insulation resistance

20 MΩ or more (500 VDC)

Withstand voltage

1000 VAC 50/60 Hz 1 min

Material

Case: SUS316L, Display: PES,
Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual, Certification/Identification label (FDA)

Weight

*1 Includes I-DATUM feature
*2 Display reading used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds “-99”, “-FF” is displayed.
*3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*4 M8 connector (3-pin) type does not include the external input function.
*5 Have passed resistance tests with cleaning agents from multiple manufactures.