0-line connection

Response time

660 µs to1.2 ms *1

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Yellow LED

Timer function

ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable)

External calibration input signal

Control output


Stability output


Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Multiple connections to expansion units

Up to 16 expansion units can be connected (a total of 17 units)


Power voltage

12 to 24 VDC ±10% *3

Current consumption.

35 mA max.

Environmental resistance

Operating temperature range

-10 to +55°C 14 to 131°F, No freezing*4

Operating ambient humidity

35 to 85% RH (No condensation)


10 to 55 Hz, double amplitude 1.5 mm 0.06", 2 hours for each of X,Y,Z axis

Shock resistance

500 m/s2 3280.8' in X, Y, and Z directions, 3 times respectively

Case material

Body/Cover: Polycarbonate


Approx. 20 g *5

*1 The response speed varies depending on the number of units connected.
*2 There is no control output cable for the PS-T0. Control output for the PS-T0 is sent from the FS-R0.
*3 Power for the PS-T2 (P)/T0 is supplied through the PS-T1, FS-T1, FS-M1 or FS-R0.
*4 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
When 3 to 10 units: -10 to +50°C 14 to 122°F
When 11 to 16 units: -10 to +45°C 14 to 113°F
When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.
*5 The PS-T0 has no cable.