CMOS Analog Laser SensorIA series

IA-030

Sensor Head

SPECIFICATIONS

Select Language

Model

IA-030

Reference distance

30 mm 1.18"

Measurement range

20 to 45 mm 0.79" to 1.77"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 1 (FDA (CDRH) Part1040.10)*1
Class 1 (IEC 60825-1)

Output

220 μW

Spot diameter (at standard distance)

Approx. 200 × 750 μm 7.89 x 29.53 Mil

Linearity

±0.1% of F.S. (F.S.=±5 mm 0.20",
25 to 35 mm 0.98" to 1.38")*2

Repeatability

2 μm 0.08 Mil *3

Sampling cycle

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser warning: Green LED, Analog output: Red LED, Measurement center: Green LED

Temperature characteristics

0.05% of F.S./°C (F.S.=±5 mm 0.20",
25 to 35 mm 0.98" to 1.38")

Environmental resistance

Enclosure rating

IP67

Operating ambientluminance

Incandescent lamp: 5000 lux*4

Operating temperature range

-10 to +50°C 14 to 122°F (No condensation or freezing)

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, Double amplitude 1.5 mm 0.06" in the X, Y and Z directions, 2 hours respectively

Material

Housing material: PBT Metal parts: SUS304 Packing: NBR Lens cover: Glass Cable: PVC

Weight

Approx 120 g (including cable)

*1 The classification is implemented based on IEC 60825-1 following the requirement of Laser Notice No.50 of FDA (CDRH).
*2 Value when measuring the KEYENCE standard target (white diffuse object).
*3 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16.
*4 Value when the sampling rate is set to 2 ms or 5 ms.