Multi-Purpose CCD Laser Micrometer
| Model | IG-010 |
IG-028 | |||
| Operation principle | CCD method | ||||
|
Light source | Wavelength | 660 nm (Visible light semiconductor laser) | |||
| Laser Class |
Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10) *6 | ||||
| Output | 62 μW | ||||
| Pulse duration | 48 μs | ||||
|
Mounting distance | 0 to 1000 mm 39.37" |
0 to 1500 mm 59.06" | |||
| Measurement range | 10 mm 0.39" | 28 mm 1.10" |
|||
|
Sampling cycle |
980 μs (When the number of times for averaging is set to [hsp]: 490 μs) | ||||
| Minimum
detectable |
High sensitivity mode |
ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94") |
|||
|
Standard mode |
ø0.2 mm ø0.007" (Setting distance: 40 mm
1.57" or
less), |
ø0.2 mm ø0.007" (Setting distance: 50 mm
1.97" or
less), |
|||
|
Repeatability *2 | 5
μm 0.20 Mil (Setting
distance: 100 mm 3.94") |
5 μm 0.20 Mil
(Setting distance: 100 mm 3.94") | |||
| Linearity *3 |
±0.28 % of F.S. (±28 μm ±1.10 Mil) |
±0.1 % of F.S. (±28 μm ±1.10 Mil) |
|||
|
Temperature characteristics *4 |
±0.03 % of F.S./°C (±3 μm ±0.12 Mil/°C) |
±0.01 % of F.S./°C (±3 μm ±0.12 Mil/°C) | |||
|
Operation indicator |
Transmitter | Optical axis alignment indicator: Green LED, Power indicator: Green LED | |||
|
Receiver | Optical axis alignment indicator: Green LED, Position monitor: Dual bar LED (Red, Green) | ||||
|
Environment |
Enclosure rating |
IP67 | |||
| Ambient temperature | -10 to +45°C (14 to 113°F) (No freezing) | ||||
| Ambient humidity | 35 to 85% RH (No condensation) | ||||
| Ambient light *5 |
Incandescent lamp: 5000 lux Sunlight: 5000 lux | ||||
|
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours | ||||
|
Material | Case | Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part) | |||
|
Lens cover | Glass | ||||
|
Cable | PVC | ||||
|
Supplied item |
Transmitter × 1, Receiver × 1, Sensor head cables (2 m 6.56') × 2 | ||||
|
Weight (including supplied items) | Approx. 380 g | Approx. 500 g |
|||
|
*1 When the measurement target object is
measured at the center position of the setting distance. When the
measurement mode is set to the glass edge mode, a glass edge of
C0.1 mm 0.003" or more can be
detected (Setting distance: 500 mm 19.69"). | |||||
| Model | IG-1000 |
IG-1050 | IG-1500 |
IG-1550 | |||
| Amplifier type | DIN rail mount | Panel mount | |||||
|
Main unit/Expansion unit | Main unit | Expansion unit |
Main unit | Expansion unit |
|||
|
Analog output |
Yes | No |
Yes | No | |||
| Power supply voltage | 10-30 VDC, Ripple (P-P): 10% included, Class 2 | ||||||
| Power
consumption |
Normal | 2700 mW or less (at 30 V: 90 mA or less) |
2880 mW or less (at 30 V: 96 mA or less) |
||||
|
Power saving function (HALF) |
2300 mW (at 30 V: 77 mA or less) | ||||||
| Power saving function (ALL) | 2200 mW (at 30 V: 74 mA or less) | ||||||
| Digital display method | Dual 7-seg
display | Dual 7-seg
display |
|||||
|
Display range |
-99.999 to +99.999, -99.99 to +99.99, -99.9 to +99.9, -99 to +99 (selectable) | ||||||
| Display resolution | 1 μm 0.04 Mil, 10 μm 0.39 Mil, 100 μm 3.94 Mil, 1000 μm 39.37 Mil(selectable ) | ||||||
|
Output | Judgement
output |
NPN (PNP) open collector x3ch, 30 VDC (Power
supply voltage) or less, residual voltage 1 V (2 V) or
less, | |||||
| Response time (judgement output) | 1.96 to 4031.72 ms *4 | ||||||
| Edge check
output |
NPN (PNP) open collector x1ch, 30 VDC (Power
supply voltage) or less, residual voltage 1 V (2 V) or
less, |
||||||
|
Analog output |
Voltage output | Output range | ±5 V (full scale 10 V) | ||||
| Output resistance | 100 Ω | ||||||
| Maximum load resistance | - | ||||||
| Repetition accuracy | ±1 mV | ||||||
| Display accuracy | ±0.05% of F.S. |
||||||
|
Temperature characteristics |
±0.005% of F.S./°C | ||||||
| Update cycle |
Same as sensor head sampling cycle | ||||||
| Response time | Same as Response time (judgement output) | ||||||
| Time constant *2 |
10 μs (90% response) | ||||||
| Current output | Output range |
4-20 mA (full scale 16 mA) |
|||||
| Output resistance | - |
||||||
| Maximum load resistance | 350 Ω | ||||||
|
Repetition accuracy |
±1.5 μA | ||||||
| Display accuracy | ±0.25% of F.S. |
||||||
|
Temperature characteristics |
±0.01% of F.S./°C | ||||||
| Update cycle |
Same as sensor head sampling cycle | ||||||
| Response time | Same as Response time (judgement output) | ||||||
| Time constant *2 |
30 μs (90% response) | ||||||
| Input | Gain input |
Input time: 20 ms or more, Response delay time: 120 ms or less (Nonvolatile memory (EEPROM) 1.5 s or less) |
|||||
|
Reset input | Input time: 20 ms or more, Response delay time: 20 ms or less |
||||||
|
Timing input | Input time: 2 ms or more, Response delay time: 2 ms or less | ||||||
| Zero shift input | Input time: 20 ms or more, Response delay time: 20 ms or less |
||||||
|
Bank A input/Bank B input |
Input time: 20 ms or more, Response delay time: 20 ms or less *4 | ||||||
| Laser emission stop input | Input time: 2 ms or more, Response delay time: 2 ms or less | ||||||
|
Environment |
Ambient temperature |
-10 to +50°C (14 to 122°F) (No freezing) | |||||
|
Ambient humidity |
35 to 85%RH (No condensation) | ||||||
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours | ||||||
| Pollution degree | 2 |
||||||
|
Material | Main unit case/Front sheet: Polycarbonate, Key top: Polyacetal, Cable: PVC | ||||||
|
Supplied item | Main body × 1, Instruction manual × 1 | Main body × 1 | Main body × 1, Panel
mounting bracket × 1, Front protection cover ×
1, | Main body × 1, Panel
mounting bracket × 1, Front protection cover ×
1, | |||
|
Weight (including supplied items) | Approx. 150 g | Approx. 140 g |
Approx. 170 g | Approx. 165 g | |||
| *1 The power
consumption with slave units installed is the total of each
amplifier unit’s power
consumption. |
|||||||
1-888-KEYENCE