| Type |
Negative pressure |
Positive pressure |
Compound pressure |
| Model |
NPN |
AP-31K |
AP-32K |
AP-33K |
AP-34K |
| PNP |
AP-31KP |
AP-32KP |
AP-33KP |
AP-34KP |
| Response time |
2.5/5/100/500 ms (selectable) |
|
 |
 |
 |
 |
| Rated pressure |
0 to 29.9 inchHg
(0 to -101.3 kPa) |
0 to 14.50 Psi
(0 to 100.0 kPa) |
0 to 145.0 Psi
(0 to 1.000 MPa) |
29.9 to -29.9 inchHg
(101.3 to -101.3 kPa) |
| Proof pressure |
72.5 Psi (490 kPa) |
72.5 Psi (490 kPa) |
217.5 Psi (1.47 MPa) |
72.5 Psi (490 kPa) |
| Pressure type |
Gauge pressure |
| Fluid types |
Air or non-corrosive gases |
| Resolution |
0.1 inchHg,
0.1 kPa, 1 mmHg,
0.001 bar |
.02 Psi, 0.1 kPa,
0.001kgf/cm , 0.001 bar |
0.2 Psi, 0.001 Mpa,
0.01kgf/cm , 0.01 bar |
0.1 inchHg,
0.2 kPa, 2 mmHg,
0.002 bar |
| Detectable pressure range |
15% to +110% of F.S. |
| Repeatability |
± 0.2% of F.S. (5 ms or more) |
| Control output |
100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C. selectable) |
| Analog output |
1 to 5 V (Load impedance: 47 k Ω min.) |
| Power supply |
12 to 24 VD± 10% |
| Ambient temperature |
0 to 50°C (32 to 122°F), No condensation |
| Relative humidity |
35 to 85%, No condensation |
| Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,
Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable |