Ultra High Speed Sensing Ionizer Hybrid Type
SJ-E series
Specs Ultra High Speed Sensing Ionizer Hybrid Type SJ-E series
Small flow model
Model |
SJ-E036L |
SJ-E060L |
SJ-E084L |
SJ-E108L |
SJ-E132L |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V*1 |
|||||||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm output |
||||||||
Alarm output |
||||||||
Communication function |
Remote control communication |
|||||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||||||
Effective length |
440 mm 17.32"*3 |
680 mm 26.77"*3 |
920 mm 36.22"*3 |
1160 mm 45.67"*3 |
1400 mm 55.12"*3 |
|||
Total length |
350 mm 13.78" |
560 mm 22.05" |
800 mm 31.50" |
1040 mm 40.94" |
1280 mm 50.39" |
|||
No. ofelectrodes |
5 |
9 |
13 |
17 |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
670 g 23.63oz |
850 g 29.98oz |
1070 g 37.74oz |
1270 g 44.80oz |
1500 g 52.91oz |
|||
*1 Measured under the following conditions. |
Small flow model
Model |
SJ-E156L |
SJ-E180L |
SJ-E204L |
SJ-E252L |
SJ-E300L |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V*1 |
|||||||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm output |
||||||||
Alarm output |
||||||||
Communication function |
Remote control communication |
|||||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||||||
Effective length |
1640 mm 64.57"*3 |
1880 mm 74.02"*3 |
2120 mm 83.46"*3 |
2600 mm 102.36"*3 |
3080 mm 121.26"*3 |
|||
Total length |
1520 mm 59.84" |
1760 mm 69.29" |
2000 mm 78.74" |
2480 mm 97.64" |
2960 mm 116.54" |
|||
No. ofelectrodes |
25 |
29 |
33 |
41 |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
1700 g 59.97oz |
1900 g 67.02oz |
2100 g 74.08oz |
2500 g 88.19oz |
2900 g 102.29oz |
|||
*1 Measured under the following conditions. |
High-end model
Model |
SJ-E036H |
SJ-E060H |
SJ-E084H |
SJ-E108H |
SJ-E132H |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V*1 |
|||||||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm output |
||||||||
Alarm output |
||||||||
Communication function |
Remote control communication |
|||||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||||||
Effective length |
420 mm 16.54"*3 |
660 mm 25.98"*3 |
900 mm 35.43"*3 |
1140 mm 44.88"*3 |
1380 mm 54.33"*3 |
|||
Total length |
350 mm 13.78" |
560 mm 22.05" |
800 mm 31.50" |
1040 mm 40.94" |
1280 mm 50.39" |
|||
No. ofelectrodes |
9 |
17 |
25 |
33 |
41 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
680 g 23.99oz |
870 g 30.69oz |
1100 g 38.80oz |
1300 g 45.86oz |
1550 g 54.67oz |
|||
*1 Measured under the following conditions. |
High-end model
Model |
SJ-E156H |
SJ-E180H |
SJ-E204H |
SJ-E228H |
SJ-E252H |
SJ-E300H |
|||
Image |
|
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
||||||||
Structure |
Shockless resistive coupling type |
||||||||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
||||||||
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
Ion balance |
±30 V*1 |
||||||||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
||||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
|||||||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
|||||||
Condition alarm output |
|||||||||
Alarm output |
|||||||||
Communication function |
Remote control communication |
||||||||
Major functions |
Condition alarm, ion level alarm, alarm output |
||||||||
Air connection port |
Rc 1/8 |
||||||||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
||||||||
Effective length |
1620 mm 63.78"*3 |
1860 mm 73.23"*3 |
2100 mm 82.68"*3 |
2340 mm 92.13"*3 |
2580 mm 101.57"*3 |
3060 mm 120.47"*3 |
|||
Total length |
1520 mm 59.84" |
1760 mm 69.29" |
2000 mm 78.74" |
2240 mm 88.19" |
2480 mm 97.64" |
2960 mm 116.54" |
|||
No. ofelectrodes |
49 |
57 |
65 |
73 |
81 |
97 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
|||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
||||||||
Overvoltage category |
I |
||||||||
Pollution degree |
2 |
||||||||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
|||||||
Relative humidity |
35 to 85% RH (no condensation) |
||||||||
Material |
Electrode probe |
Tungsten |
|||||||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
Weight |
1750 g 61.73oz |
1950 g 68.78oz |
2150 g 75.84oz |
2350 g 82.89oz |
2600 g 91.71oz |
3000 g 105.82oz |
|||
*1 Measured under the following conditions. |
Standard model
Model |
SJ-E036A |
SJ-E060A |
SJ-E084A |
SJ-E108A |
SJ-E132A |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V*1 |
|||||||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm output |
||||||||
Alarm output |
||||||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||||||
Effective length |
420 mm 16.54"*3 |
660 mm 25.98"*3 |
900 mm 35.43"*3 |
1140 mm 44.88"*3 |
1380 mm 54.33"*3 |
|||
Total length |
350 mm 13.78" |
560 mm 22.05" |
800 mm 31.50" |
1040 mm 40.94" |
1280 mm 50.39" |
|||
No. ofelectrodes |
5 |
9 |
13 |
17 |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
670 g 23.63oz |
850 g 29.98oz |
1070 g 37.74oz |
1270 g 44.80oz |
1500 g 52.91oz |
|||
*1 Measured under the following conditions. |
Standard model
Model |
SJ-E156A |
SJ-E180A |
SJ-E204A |
SJ-E228A |
SJ-E252A |
SJ-E300A |
|||
Image |
|
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
||||||||
Structure |
Shockless resistive coupling type |
||||||||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
||||||||
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
Ion balance |
±30 V*1 |
||||||||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
||||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
|||||||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
|||||||
Condition alarm output |
|||||||||
Alarm output |
|||||||||
Major functions |
Condition alarm, ion level alarm, alarm output |
||||||||
Air connection port |
Rc 1/8 |
||||||||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
||||||||
Effective length |
1620 mm 63.78"*3 |
1860 mm 73.23"*3 |
2100 mm 82.68"*3 |
2340 mm 92.13"*3 |
2580 mm 101.57"*3 |
3060 mm 120.47"*3 |
|||
Total length |
1520 mm 59.84" |
1760 mm 69.29" |
2000 mm 78.74" |
2240 mm 88.19" |
2480 mm 97.64" |
2960 mm 116.54" |
|||
No. ofelectrodes |
25 |
29 |
33 |
37 |
41 |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
|||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
||||||||
Overvoltage category |
I |
||||||||
Pollution degree |
2 |
||||||||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
|||||||
Relative humidity |
35 to 85% RH (no condensation) |
||||||||
Material |
Electrode probe |
Tungsten |
|||||||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
Weight |
1700 g 59.97oz |
1900 g 67.02oz |
2100 g 74.08oz |
2300 g 81.13oz |
2500 g 88.19oz |
2900 g 102.29oz |
|||
*1 Measured under the following conditions. |