Static-Sensing IonizerSJ-H series

SJ-H084A

Bar Type Main Unit, Standard Model 840 mm

SPECIFICATIONS

Select Language

Model

SJ-H084A

Type

HA

Ion generation method

Corona discharge method

Structure

Shock-proof, resistance-coupled type

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C.

Ion balance

±30 V*1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photo-relay, 100 mA max. (40 V max.)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less

Effective length

840 mm33.07"*2

No. ofelectrodes

12

Dimensions

Total length (A)

840 mm33.07"*2

Static elimination bar length (B)

800

Mounting pitch (C)

825

Electrode pitch and length (D)

P60 x 11 = 660

Nozzle pitch and length (E)

P120 x 5 = 600

Rating

Power voltage

24 to 36 VDC ±10%

Current consumption.

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Environmental resistance

Overvoltage category

I

Pollution degree

2

Operating temperature range

0 to +40℃ 32°F to 104°F

Operating ambient humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Tungsten

Main unit

ABS resin/PC

Weight

Controller

Static elimination bar

980 g

*1 The value is measured under the following condition.
*2 The effective length is determined based on the static elimination range at a
distance of 50 mm 1.97".

  • KEYENCE Information Network - Ionizing Static Eliminators

STATIC ELECTRICITY Knowledge

  • General Catalog Request
  • Trade Shows and Exhibitions
  • eNews Subscribe

Static Eliminators / Ionizers