High-performance Compact Static EliminatorSJ-M series


Spot Type Main Unit, Head Cable 2-m and CAB Needle


Select Language




Static Elimination Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max. *1

Ion balance

±15 V or less *2

Max. air pressure

0.001 to 0.5 MPa *3

Min. air pressure

With SJ-ML

0.02MPa (20Nl/min)

With SJ-MS/ML1

0.03MPa (20Nl/min)

With SJ-MS/ML2

0.02MPa (20Nl/min)

With SJ-MS/ML3

0.08MPa (50Nl/min)

With SJ-MS/ML4

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output


Power voltage

24 VDC ±10%

Current consumption.

450 mA max.

Environmental resistance

Operating temperature range

0 to 80°C 32 to 176°F*4*5

Operating ambient humidity

35 to 65% RH


Approx 600 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30°C 68 to 86°F, relative humidity 40 to 60%)
*2 Values obtained at an installation distance of 50 mm 1.97"
and air flow rate of 20 Nl/min [ambient operating temperature
+20 to +30°C +68 to +86°F, ambient operating humidity 40
to 60% RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding
+35°C 95°F. Use clean or dry air at a temperature of -20°C -4°F or
less. Min. air pressure varies by nozzle used.
*4 Use a supplied fluid with a temperature of 40°C 104°F or less.
*5 Only for the pressure cable. Other parts should be used with an ambient temperature of 0 to 40°C 104°F.

  • KEYENCE Information Network - Ionizing Static Eliminators


Latest / Most Downloaded

    • General Catalog Request
    • Trade Shows and Exhibitions
    • eNews Subscribe

    Static Eliminators / Ionizers