High-performance Compact Static EliminatorSJ-M series


Spot Type Amplifier Unit


Select Language




Controller Unit

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max. *1

Ion balance

±15 V or less *2

Max. air pressure

0.001 to 0.5 MPa *3

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output


Power voltage

24 VDC ±10%

Current consumption.

450 mA max.

Environmental resistance

Operating temperature range

0 to +40℃ 32°F to 104°F

Operating ambient humidity

35 to 65% RH


Approx 300 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30°C 68 to 86°F, relative humidity 40 to 60%)
*2 Values obtained at an installation distance of 50 mm 1.97"
and air flow rate of 20 Nl/min [ambient operating temperature
+20 to +30°C +68 to +86°F, ambient operating humidity 40
to 60% RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding
+35°C 95°F. Use clean or dry air at a temperature of -20°C -4°F or
less. Min. air pressure varies by nozzle used.