Autofocus 1D and 2D Code ReaderSR-1000 series

SR-1000W

Automatic Focus Code Reader

SPECIFICATIONS

Select Language

Model

SR-1000W

Type

Wide-field type

Receiver

Sensor

CMOS Image Sensor

Number of pixels

1280 × 1024 pixels

Light emitter

Illumination light source

High intensity red LED

Pointer light source

High intensity green LED

Focus adjustment

Autofocus*1

I/O specifications

Control input

Number of Inputs

2

Input type

Bidirectional voltage input

Maximum rating

26.4 VDC

Minimum ON voltage

15 VDC

Maximum OFF current

0.2 mA or less

Control output

Number of Outputs

3

Output type

Photo MOS relay output

Maximum rating

30 VDC

Maximum load current

1 output : 50 mA or less, Total of 3 outputs : 100 mA or less

Leakage current when OFF

0.1 mA or less

Residual voltage when ON

1 V or less

Ethernet

Communication standard

IEEE 802.3 compliant, 10BASE-T/100BASE-TX

Supported protocol

TCP/IP, SNTP, FTP, BOOTP, MC Protocol, Omron PLC link, KV STUDIO, EtherNet/IPTM, PROFINET

Serial communication

Communication standard

RS-232C compliant

Transmission speed

9600, 19200, 38400, 57600, 115200 bps

Supported protocol

No-protocol, MC Protocol, SYSWAY, KV STUDIO

USB

Communication standard

USB 2.0 Full Speed compliant

Reading specifications

Supported symbol

2D

QR, MicroQR, DataMatrix (ECC200), GS1 DataMatrix, PDF417, Micro PDF417, GS1 Composite (CC-A, CC-B, CC-C)

Barcode

CODE39, ITF, 2of5 (Industrial 2of5), COOP 2of5, NW-7 (Codabar), CODE128,
GS1-128, GS1 DataBar, CODE93, JAN/EAN/UPC,
Trioptic CODE39, CODE39 Full ASCII, Pharmacode

Minimum
resolution

2D

0.082 mm 0.003"

Barcode

Reading distance

50 to 600 1.97" to 23.62"

Field of view for reading

257 × 206 mm 10.12" x 8.11"
(Typical example at 400 mm 15.75")

Rating

Power voltage

24 VDC ±10%

Current consumption.

Approx 700 mA

Environmental
resistance

Enclosure rating

IP65

Environmental resistance

Operating temperature range

0 to +45°C 32 to 113°F

Ambient temperature for storage

-10 to +50°C 14 to 122°F

Operating ambient humidity

35 to 85% RH (No condensation)

Environmental
resistance

Storage ambient humidity

Environmental resistance

Operating ambientluminance

Sunlight : 10000 lux, Incandescent lamp : 6000 lux, Fluorescent lamp : 2000 lux

Operating environment

No dust or corrosive gas present

Vibration

10 to 55 Hz Double amplitude 0.75 mm 0.030", 3 hours each in X, Y and Z directions

Weight

Approx 200 g

*1 The focal position can be adjusted automatically during installation.

Auto ID Library

  • KEYENCE TV Autofocus Code reader SR-1000
  • traceability solutions
  • General Catalog Request
  • Trade Shows and Exhibitions
  • eNews Subscribe

Vision / Auto ID