3D Printers for Manufacturing Sites
GX-1000 series
Specs 3D Printers for Manufacturing Sites GX-1000 series
3D Printer main unit
|
Model |
GX-1000 |
|||
|
Image |
|
|||
|
Method |
FFF (fused filament fabrication) method |
|||
|
Print head |
Independent dual heads |
|||
|
Nozzle diameter |
0.4 mm 0.016", 0.8 mm 0.03" (special wear-resistant nozzle) |
|||
|
Print resolution |
Default: 200 μm 7.874 Mil; smallest: 100 μm 2.539 Mil. |
|||
|
Printing size (single) |
400 × 300 × 300 mm 15.75" × 11.81" × 11.81" *345 × 300 × 300 mm 13.58" × 11.81" × 11.81" in dual build mode |
|||
|
Materials (model materials) |
GX-M1, GX-H1, GX-T1, GX-E1 |
|||
|
Material (support material) |
GX-S1 |
|||
|
Size (width, depth, height) |
750 × 610 × 680 mm 29.53" × 24.02" × 26.77" (excluding protrusions) / 750 × 630 × 710 mm 29.53" × 24.80" × 27.95" (including handles and legs) |
|||
|
Weight |
69 kg 152.12 lb |
|||
|
Power voltage |
Single phase 100–120 V ±10%, 50/60 Hz |
|||
|
Power consumption (maximum) |
1500 VA |
|||
|
Power consumption (normal) |
1000 VA (@100 VAC) / 1400 VA (@120 VAC) |
|||
|
Applicable regulations |
EU Directives (EMC Directive, Machinery Directive, RoHS Directive) / EN Standards (EN61326-1, EN60204-1, EN63000) / UL Standards (UL2011) / |
|||
|
Interface |
Ethernet (100BASE-TX), USB2.0, touch panel |
|||
|
Software |
GX Slicer |
|||
|
Supported OS |
Windows® 10 64 bit / Windows® 11 64 bit |
|||
|
Input file format |
STL, STEP, 3MF |
|||
|
Additional functions |
Printing plate auto-calibration, in-chamber temperature control, printing plate temperature control |
|||
|
Environmental resistance |
Ambient temperature |
10 to 40°C 50°F to 104°F |
||
|
Relative humidity |
85%RH or lower |
|||
Filament dryer
|
Model |
OP-89111 |
|||
|
Image |
|
|||
|
Size (width, depth, height) |
200 × 280 × 380 mm 7.87" × 11.02" × 14.96" |
|||
|
Weight |
2.7 kg 5.95 lb |
|||
|
Power voltage |
Single phase 100–120 / 200–240 VAC ±10% 50/60 Hz |
|||
|
Power consumption (maximum) |
250 VA (@100–120 VAC) / 600 VA (@200–240 VAC) |
|||
|
Power consumption (normal) |
90 VA (@100–120 VAC) / 100 VA (@200–240 VAC) |
|||
|
Applicable regulations |
EU Directives (EMC Directive, Low Voltage Directive, RoHS Directive) / EN Standards (EN61326-1, EN61010-1, EN63000) / UL Standards and CSA |
|||
|
Additional functions |
Cover open/close detection function, fall detection function |
|||
|
Environmental resistance |
Ambient temperature |
10 to 40°C 50°F to 104°F |
||
|
Relative humidity |
85%RH or lower*1 |
|||
|
*1 For high-quality printing, we recommend using the product at 35°C 95°F 80%RH or less. |
||||