Image Dimension Measurement System

IM-6000 series

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Heads with the contact height measurement unit IM-6225T

IM-6225T - Heads with the contact height measurement unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • CSA

Specifications

Model

IM-6225T

Type

Head

Image sensor

1" 6.6 mega pixel monochrome CMOS

Display

10. 4" LCD monitor (XGA: 1024 × 768)
External monitor connectable (clone output)

Receiver lens

Double telecentric lens

Image
measurement

Field of view

Wide field: ø100 × L200 mm ø3.94" × 7.87", High precision: 25 × L125 mm 0.98" × 4.92"

Minimum display unit

0.1 µm

Repetition accuracy

W/o stage movement

Wide field: ±1 µm, High precision: ±0. 5 µm

With stage movement

Wide field: ±2 µm, High precision: ±1. 5 µm

Measurement accuracy (±2σ)

W/o binding

Wide field: ±5 µm*1, High precision: ±2 µm*2

With binding

Wide field: ±(7 + 0. 02 L) µm*3, High precision: ±(4 + 0. 02 L) µm*4

Height measurement

Measuring range

0 to 60 mm 0 to 2.36"

Measurement force

0.3 N

Measurement position accuracy (XY)

±0.7 mm ±0.03"

Minimum display unit

1 µm

Measurable area (XY)

Standard probe

Wide field: 45 × 95 mm 1.77" × 3.74", High precision: 7.5 × 25 mm 0.30" × 0.98"

Wide-range probe

Wide field: 95 × 95 mm 3.74" × 3.74", High precision: 60 × 25 mm 2.36" × 0.98"

Repetition accuracy

Standard probe

±2 µm*5

Wide-range probe

±5 µm*5

Measurement accuracy

Standard probe

±7.5 µm*6

Wide-range probe

±15 µm*6

External remote input

Non-voltage input (with and without contact)

External output

OK/NG/FAIL/MEAS

Relay output/rated load: 24 VDC, 0. 5 A/ON resistance

Interface

LAN

RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)

USB 2.0 series A

6 ports (front: 2, rear: 4)

Record

Hard disk drive

250 GB

Illumination system

Transparent

Telecentric transparent illumination

Ring

Four division, multi-angle illumination (electric)
Slit ring (directivity) illumination (electric)

X stage

Moving range

100 mm 3.94" (electric)

Z stage

30 mm 1.18" (electric)

Withstand load

2 kg

Power supply

Power voltage

100 to 240 VAC 50/60 Hz

Power consumption

310 VA max.

Environmental resistance

Ambient temperature

+10 to +35 °C 50 to 95 °F

Relative humidity

20 to 80 % RH (No condensation)

Weight

Approx. 34 kg

*1 In the range of ø80 mm ø3.15" from the center of the stage within the operating ambient temperature range of +23°C ±1.0°C +73.4°F ±33.8°F at the focused focal point position
*2 In the range of ø20 mm ø0.79" from the center of the stage within the operating ambient temperature range of +23°C ±1.0°C +73.4°F ±33.8°F at the focused focal point position
*3 In the range of ø80 × 180 mm ø3.15" × 7.09" from the center of the stage, within the operating ambient temperature range of +23°C ±1.0°C +73.4°F ±33.8°F at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units)
*4 In the range of ø20 × 120 mm ø0.79" × 4.72" from the center of the stage, within the operating ambient temperature range of +23°C ±1.0°C +73.4°F ±33.8°F at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units)
*5 When the maximum measurement height is set to 30 mm 1.18" or less; ±3 µm for the standard probe and ±6 µm for the wide-range probe when the maximum measurement height is greater than 30 mm 1.18" and less than or equal to 60 mm 2.36"
*6 When the maximum measurement height is set to 30 mm 1.18" or less; ±12 µm for the standard probe and ±21 µm for the wide-range probe when the maximum measurement height is greater than 30 mm 1.18" and less than or equal to 60 mm 2.36"

Data Sheet (PDF) Other Models