Recent Searches
    Series ()
      Models ()
        Keywords

          High-Accuracy Digital Contact SensorGT2 series

          GT2-A12K

          Sensor Head, High-precision Type, Air Cylinder Model

          SPECIFICATIONS

          Select Language

          Model

          GT2-A12K

          Detection system

          Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

          Measuring range

          12 mm 0.47"

          Resolution

          0.1 μm 0.004 Mil

          Indicated accuracy

          1 µm 0.04 Mil (p-p)*1

          Measuring force

          Downward mounting

          1.2 N*2

          Side mounting

          1.1 N*2

          Upward mounting

          1.0 N*2

          Sampling cycle

          1 ms

          Fluid used

          Dry air

          Operation indicator light

          2-color LED (red, green)

          Environmental resistance

          Enclosure rating

          IP67*3

          Pressure resistance

          1 MPa

          Applied pressure range

          0.25 to 0.5 MPa

          Ambient temperature

          0 to +55 °C 32 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          1,000 m/s2 (IEC60068-2-27)

          Materials

          Main body

          Main body case: Zinc die-casting; Cylinder part: Aluminium alloy;
          Air joint resin part: Polyacetal; Air joint metal part: Brass nickel plating; Indicator: Polyarylate

          Dust boot

          NBR

          Contact

          TYPE304 Stainless steel, super-tough tungsten alloy*4

          Sensor head cable

          Optional (connect to the M8 connector)

          Weight

          Approx. 145 g (excluding cable)

          *1 Value when the ambient temperature is 20 °C 68 °F.
          *2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
          *3 Make sure the air tube is connected to the air exhaust joint and that no foreign materials enter inside from the joint.
          *4 The contact is included with the sensor.