          SPECIFICATIONS

          Select Language

          Model

          IX-1000

          Main unit / expansion unit

          Main unit

          Display

          Min. display unit

          10 µm*1

          Display range

          ±999.99 to ±999 mm (with 4 selectable steps)*1

          Tools

          Scan mode

          Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment
          (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2

          Line mode

          Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction
          (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2

          Other functions

          Common

          ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement,
          Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor,
          Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security

          Scan mode

          Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination,
          Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) ,
          Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range

          Line mode

          Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)

          Input

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Input

          Number of inputs

          8 (IN1 to IN8)

          Function

          IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions
          Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)

          Output

          Open collector output; NPN/PNP switchable, N.O./N.C. switchable
          For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or less
          For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less

          Output

          Number of inputs

          10 (OUT1 to OUT10)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result,
          Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm

          Analog voltage output

          ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω*3

          Analog current output

          4 to 20 mA, max. load resistance: 350 Ω*3

          Number of programs

          32

          Statistical information

          Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
          Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*4

          Detection history

          Saved history

          100*5

          Save conditions

          Selectable from NG only / All*5

          Ethernet

          Standard

          100BASE-TX/10BASE-T*6

          Connector

          RJ45 8-pin connector*6

          Interface compatibility

          CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7

          Number of connectible units

          Main units: 1, Expansion units: 1, Communication units (DL) : 1

          Ratings

          Power voltage

          24 VDC ±10 % (including ripple)

          Current consumption

          Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*8

          Environmental resistance

          Ambient temperature

          0 to +50°C 32 to 122°F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/
          Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/
          Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC

          Weight

          Approx. 210 g

          *1 For displaying on an IX Series control panel or PC software.
          *2 Configurable for each program.
          *3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
          *4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
          *5 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software.
          *6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
          *7 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
          *8 Includes a DL Series communication unit.

          Tips of Measurement